| Technical data |
| SPD according to EN 61643-31 / IEC 61643-31 | type 2 / class II |
| Max. PV voltage (UCPV) | 1500 V |
| Short-circuit withstand capability (ISCPV) | 10 kA |
| Total discharge current (8/20 µs) (Itotal) | 40 kA |
| Nominal discharge current (8/20 µs) [(DC+/DC-) -- PE] (In) | 15 kA |
| Max. discharge current (8/20 µs) [(DC+/DC-) -- PE] (Imax) | 40 kA |
| Voltage protection level (UP) | ≤ 5 kV |
| Nominal load current (d.c.) (IL) | 40 A |
| Response time (tA) | ≤ 25 ns |
| Operating temperature range (TU) | -40 °C ... +80 °C |
| Operating state / fault indication | green / red |
| Number of ports | 1 |
| Cross-sectional area (min.) | 1.5 mm2 solid, 6 mm2 fine stranded |
| Cross-sectional area (max.) | 10 mm2 solid / fine stranded |
| Cross-sectional area (min.) with wire end ferrule | 1.5 mm² |
| Cross-sectional area (max.) with wire end ferrule | 6 mm² |
| Cross-sectional area (max.) with wire end ferrule without collar | 10 mm² |
| For mounting on | 35 mm DIN rails acc. to EN 60715 |
| Enclosure material | thermoplastic, red, UL 94 V-0 |
| Place of installation | indoor installation |
| Degree of protection | IP 20 |
| Capacity | 3 Standard DIN module, DIN 43880 |
| Type of remote signalling contact | changeover contact |
| Switching capacity (a.c.) | 250 V / 0.5 A |
| Switching capacity (d.c.) | 250 V / 0.1 A; 125 V / 0.2 A; 75 V / 0.5 A |
| Cross-sectional area for remote signalling terminals | max. 1.5 mm2 solid / flexible |
Multipole surge arrester DEHNguard MP YPV, type 2 according to EN 61643-31, consisting of a base part with plugged-in protection modules and a double push-in connection terminal suitable for branch and through wiring. High device safety due to arrester monitoring with thermo-dynamic control. For protecting low-voltage consumer systems against overvoltages. For use in accordance with IEC 60364-7-712:2002-05 (installation of photovoltaic supply systems).