DEHN 941310, EAN: 4013364131798

DEHN 941310 DSH TT 255 combo surge arrester TT-TN-S

Installation > Grounding Systems > Lightning protection material

DEHN 941310 DSH TT 255 combo surge arrester TT-TN-S

Lieske Part No. 306477
Mfg Part No 941310
EAN-Code 4013364131798
Manufacturer DEHN
Here only 825,55 EUR
982,40 EUR incl. VAT

Further information for DEHN 941310 DSH TT 255 combo surge arrester TT-TN-S

General
SPD according to EN 61643-11 / IEC 61643-11type 1 + type 2 / class I + class II
Energy coordination with terminal equipment (≤ 10 m)type 1 + type 2 + type 3
Nominal voltage (a.c.) (UN)230 / 400 V (50 / 60 Hz)
Max. continuous operating voltage (AC) (UC)255 V (50 / 60 Hz)
Lightning impulse current (10/350 µs) [L1+L2+L3+N-PE] (Itotal)50 kA
Specific energy [L1+L2+L3+N-PE] (W/R)625.00 kJ/Ohm
Lightning impulse current (10/350) [L-N]/[N-PE] (Iimp)12.5 / 50 kA
Specific energy [L-N]/[N-PE] (W/R)39.06 / 625.00 kJ/Ohm
Nominal discharge current (8/20 µs) [L-N]/[N-PE] (In)12.5 / 50 kA
Voltage protection level [L-N]/[N-PE] (UP)≤ 1.5 / ≤ 1.5 kV
Follow current extinguishing capability [L-N]/[N-PE] (Ifi)25 kArms / 100 Arms
Follow current limitation / Selectivityno tripping of a 32 A gG fuse up to 25 kArms (prosp.)
Response time (tA)≤ 100 ns
Max. mains-side overcurrent protection160 A gG
Temporary overvoltage (TOV) [L-N] (UT) – Characteristic440 V / 120 min. – withstand
Temporary overvoltage (TOV) [N-PE] (UT) - Characteristic1200 V / 200 ms – withstand
Operating temperature range (TU)-40 °C ... +80 °C
Operating state / fault indicationgreen / red
Number of ports1
Cross-sectional area (L1, L2, L3, N, PE, ) (min.)1.5 mm2 solid / flexible
Cross-sectional area (L1, L2, L3, N, PE, ) (max.)35 mm2 stranded / 25 mm2 flexible
For mounting on35 mm DIN rails acc. to EN 60715
Enclosure materialthermoplastic, red, UL 94 V-0
Place of installationindoor installation
Degree of protectionIP 20
Capacity4 Standard DIN module, DIN 43880
ApprovalsKEMA, VDE, UL
Extended technical data
Voltage protection level [L-PE] (UP)2.0 kV
The DEHN DSH TT 255 is a multipole, application-optimised combination surge arrester from the DEHNshield product family, specifically designed for TT and TN-S systems (3+1 configuration). It serves as overvoltage protection in electrical installations and meets the minimum requirements for lightning current discharge capability according to DIN VDE 0100-534. The arrester is based on spark gap technology and provides protection against overvoltages, including direct lightning strikes, through an energy-coordinated protective effect up to a distance of ≤ 10 m from the end device. This enables integrated lightning protection equipotential bonding and end device protection in compact electrical installations.

Applications
This arrester is intended for use in residential buildings and in specific applications, particularly at interfaces 0A to 2 of the lightning protection zone concept. It is designed for indoor installations and is suitable for electrical systems with nominal voltage 230/400 V (50/60 Hz). The maximum continuous voltage is 255 V AC, ensuring safe use in standard networks.

Functions and Equipment in Detail
The DSH TT 255 is classified as a Type 1 + Type 2 arrester according to EN 61643-11 / IEC 61643-11, thus providing protection against high lightning surge currents. The total lightning surge current (10/350 µs) is 50 kA, with specific energy reaching 625.00 kJ/Ohm. For individual conductors (L-N and N-PE), the values are 12.5 kA and 50 kA (Iimp), and 12.5 kA and 50 kA (In), respectively. The protection level is ≤ 1.5 kV for L-N and N-PE, ensuring effective overvoltage absorption. The follow current interruption capability is 25 kAeff (L-N) and 100 Aeff (N-PE), ensuring selectivity with respect to downstream fuses — specifically, a 35 A gG fuse up to 25 kAeff will not be triggered.

Technology Explained Simply
The technology is based on a spark gap, enabling a space-saving design requiring only 1 TE per pole. The total width is 4 TE, allowing compact mounting on a 35 mm DIN rail according to EN 60715. The response time is ≤ 100 ns, ensuring rapid reaction to overvoltages. The TOV voltage (Temporary Overvoltage) is 440 V for 120 minutes (L-N) and 1200 V for 200 ms (N-PE), ensuring robustness against transient voltage surges. The operating temperature range extends from -40 °C to +80 °C, enabling use in various environments.

Compatibility and Accessories
The arrester is designed for TT and TN-S systems and can be directly connected to network connection points. The connection cross-sections range from 1.5 mm² (min.) to 35 mm² (max.) for multi-strand conductors and 25 mm² for fine-strand conductors. Mounting is on a 35 mm DIN rail, with the housing made of thermoplastic material in red (UL 94 V-0). The protection rating IP 20 safeguards against contact with moving parts, but it is not suitable for outdoor use.

Mounting and Installation
Mounting is on a standard 35 mm DIN rail according to EN 60715. The installation dimensions correspond to 4 TE according to DIN 43880. The ready-to-connect design enables quick and secure installation. The functional and fault indication is provided via a viewing window with green (functional) and red (faulty) markings, allowing visual inspection of the arrester’s status.

Operational Advantages
The DSH TT 255 offers high protection performance with a compact design that minimises space requirements in enclosures. The energy coordination enables direct protection of end devices, often making additional arresters unnecessary. The high follow current interruption capability and selectivity with respect to downstream fuses increase the reliability of the installation. The integrated fault indication simplifies maintenance and inspection of the system.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/306477