| General |
| VLD type (EN 50122-1) | VLD-F |
| d.c. sparkover voltage (Uag) | 350 V +/- 20 % |
| Impulse sparkover voltage | ≤ 900 V (1 kV/µs) |
| Lightning current discharge capacity (10/350 µs) 0.1x / 0.5x / 1x | 2 kA |
| Lightning current carrying capability (10/350 µs) | 25 kA |
| Safe short-circuit due to welding of the electrodes in case of direct currents | ≥ 600 A / 250 ms |
| Additional short-circuit current rating | 25 kArms / 100 ms; 36 kArms / 75 ms |
| Long-term current | 1 kArms for t ≤ 120 s |
| Leakage current (Ilc) | < 1 µA for 100 V d.c. |
| Operating temperature range (TU) | -40 °C ... +80 °C |
| To be mounted with | mast adapter MA SDS M12 or SIEMENS No. 8WL6503-xx |
SDS spark gap insert for galvanic isolation of insulated track sections and earthed system parts. In cylindrical design for mounting in the rail adapter Siemens No. 8WL6503-xx