Further information for DEHN 909703 DGA FF TV surge arrester gate 75 Ohm
General
Manufacturer
DEHN
Degree of protection
Surge arrester
Connection type
F-connector
Impedance
75 Ohm
Shielding class
A
Norm
EN 50 083-2
Measurement output
Integrated
Suitable for remote power supply
Detail
SPD class
{
Max. continuous operating voltage DC (UC)
24 V
Nominal current (IN)
2 A
D1 Lightning impulse current (10/350 µs) (Iimp)
0.2 kA
C2 Nominal discharge current (8/20 µs) (In)
1.5 kA
Frequency range
d.c. / 5-3000 MHz
Connection (input / output)
F socket / F socket
The DEHN surge arrester type DGA FF TV (manufacturer's number 909703) is a device specifically developed for the protection requirements in SAT and broadband (BK) installations. It serves as protection against surges in coaxial cable systems and is designed for use in 75 Ohm installations. The arrester is suitable for remote power feeding, meaning it functions even when remote power is supplied via the coaxial cable (e.g. for antenna systems or satellite dishes). It is therefore suitable for integration into existing or newly installed TV and SAT systems without impairing remote power feeding.
Applications
The arrester is intended for use in all common TV and SAT installations, particularly in buildings equipped with coaxial cable systems for television and broadband communication. It protects sensitive end devices such as satellite dishes, receivers, set-top boxes or TV devices from transient surges caused by lightning discharges, voltage fluctuations or other electrical disturbances in the network. The space-saving design enables easy installation in distribution boxes, wall sockets or other installation shafts.
Functions and Equipment in Detail
The arrester features an integrated test output, allowing the system to be checked for proper function and grounding. This output is useful for maintenance and diagnostics of protection systems, as it enables checking the resistance value of the grounding connection. The shielding of the arrester meets the enhanced requirements of Class A according to standard EN 50 083-2. This class guarantees particularly high shielding effectiveness, which is necessary to avoid interference in high-frequency transmission systems such as SAT and BK installations.
Technology Explained Simply
The arrester operates on the principle of surge diversion: when a voltage exceeding the permissible operating voltage range occurs, it diverts the excess energy through a diversion resistor or a varistor (e.g. metal-oxide varistor) to protect downstream devices. The F-connectors at both ends allow direct connection into existing coaxial cable systems. The remote power feeding capability means that the arrester does not block the voltage transmitted via the coaxial cable for remote power (e.g. 12 V or 24 V), but allows it to pass through, ensuring that remote power feeding continues to function.
Compatibility and Accessories
The arrester is designed for 75 Ohm coaxial cable systems, which are typically used in SAT and BK installations. It is compatible with common F connectors and can be installed in existing installations without additional adapters. The EN 50 083-2 Class A standard ensures that it meets the high shielding requirements for professional and high-quality transmission systems.
Installation and Mounting
Installation is carried out by simply inserting the arrester into the existing coaxial cable, connecting the F connectors at the respective ends of the cable. The space-saving design allows installation in confined spaces, such as those found in distribution boxes or wall sockets. The integrated grounding connection must be connected to the grounding system in accordance with the relevant standards (e.g. VDE 0100) to ensure the protective function.
Advantages in Operation
The arrester provides reliable protection against surges caused by external influences such as lightning strikes or network disturbances. The remote power feeding capability ensures the functionality of the entire system, even when remote power feeding is active. The integrated test function enables easy system checking, simplifying maintenance and fault diagnosis. The shielding according to Class A of EN 50 083-2 ensures high immunity to interference and minimizes the risk of signal disturbances in transmission.