DEHN 907430, EAN: 4013364107670

DEHN 907430 DRL PD 180 surge arrester rapid LSA

Installation > Wiring systems > Cable support systems, cable trays and accessories

DEHN 907430 DRL PD 180 surge arrester rapid LSA

Lieske Part No. 475557
Mfg Part No 907430
EAN-Code 4013364107670
Manufacturer DEHN
Here only 43,60 EUR
51,88 EUR incl. VAT

Further information for DEHN 907430 DRL PD 180 surge arrester rapid LSA

General
Degree of protectionIP 20 (when plugged in)
Number of cores1 DA
Voltage protection levellow core-to-core
Over current protectionIntegrated
Mounting methodwith EF 10 DRL
CompatibilityDRL plug-in magazine
Application rangeADSL, ISDN, Uk0, a/b conductors
SPD classO
Nominal voltage (UN)180 V
Max. continuous operating voltage DC (UC)180 V
Max. continuous operating a.c. voltage (UC)127 V
Nominal current (IN)0.1 A
D1 Total lightning impulse current (10/350 µs) in combination with DRL 10 B... (Iimp)5 kA
D1 Lightning impulse current (10/350 µs) per line in combination with DRL 10 B... (Iimp)2.5 kA
C2 Total nominal discharge current (8/20 µs) in combination with DRL 10 B... (In)10 kA
C2 Nominal discharge current (8/20 µs) per line in combination with DRL 10 B... (In)5 kA
C1 Nominal discharge current (8/20 µs) per line without DRL 10 B... (In)0.25 kA
Voltage protection level line-PG for Iimp D1 in combination with DRL 10 B... (UP)≤ 500 V
Voltage protection level line-line at 1 kV/µs C3 (UP)≤ 270 V
Series impedance per line10 ohms +/- 15%
Cut-off frequency line-line (fG)61 MHz
Capacitance line-line (C)≤ 80 pF
Typeintegrated overcurrent protection
Operating temperature range (TU)0 °C ... +70 °C
Pluggable intoLSA disconnection block 2/10 or DRL 10 B... plug-in SPD block
Enclosure materialpolyamide PA 6.6
Colouryellow
Test standardsIEC 61643-21 / EN 61643-21
The DEHN DRL PD 180 is a protection plug for a single data conductor (1 DA), used as a single-stage end device protection in combination with the DRL plug magazine. It protects data lines against overvoltages, particularly in systems with ADSL, ISDN, Uk0 or a/b conductors. The surge arrester is energetically coordinated with the DRL plug magazine, ensuring safe and efficient energy dissipation during voltage surges. Installation is carried out using the EF 10 DRL, and it is recommended to install it exclusively in combination with the DRL plug magazine to fully utilize its protective functions.

Applications

The DRL PD 180 is designed for use in buildings where data lines must be protected against transient overvoltages. It is particularly suitable for applications in telecommunications, where ADSL or ISDN lines are connected, as well as for systems with Uk0 or a/b conductors. Use in combination with the DRL plug magazine enables modular and flexible installation in existing or new installation systems.

Functions and Features in Detail

The protection plug provides a low protection level between conductors (conductor-to-conductor), meaning it diverts overvoltages at relatively low voltage levels, effectively protecting sensitive end devices. An integrated overcurrent protection prevents damage to the surge arrester in case of a fault or overload, increasing the reliability and service life of the device. The energetic coordination with the DRL plug magazine ensures that dissipation energy is optimally distributed, preventing overload of individual components.

Technology Explained Simply

The DRL PD 180 operates as a single-stage surge arrester, meaning it is installed directly at the point where the data line connects to the end device. Dissipation occurs via a special semiconductor or gas discharge protection, which activates during overvoltage. The integrated overcurrent fuse protects the arrester itself from thermal overload. Installation is carried out using the EF 10 DRL, a special mounting element that securely holds the plug in the DRL plug magazine.

Compatibility and Accessories

The protection plug is exclusively intended for use in the DRL plug magazine. Installation is performed using the EF 10 DRL, a special mounting element designed for securing the plug in the magazine. Installation without the DRL plug magazine is not recommended, as full protective functions are only guaranteed when used in combination with the magazine.

Mounting and Installation

Installation is carried out by inserting the protection plug into the DRL plug magazine and securing it with the EF 10 DRL. Installation is only intended in combination with the DRL plug magazine, as energetic coordination and secure mounting are only ensured within this system.

Operational Advantages

The DRL PD 180 provides reliable protection for data lines against overvoltages, particularly in systems with ADSL, ISDN, Uk0 or a/b conductors. The integrated overcurrent fuse increases the service life and safety of the device. Energetic coordination with the DRL plug magazine ensures optimal energy dissipation and prevents overloads. The modular design enables flexible and easy installation in existing systems.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/475557
qrcode für DEHN 907430 DRL PD 180 surge arrester rapid LSA