| General |
| SPD according to EN 61643-11 / IEC 61643-11 | Type 2 / class II |
| Energy coordination with terminal equipment (≤ 10 m) | Type 2 + type 3 |
| Nominal voltage (a.c.) (UN) | 230 V (50 / 60 Hz) |
| Max. continuous operating voltage (AC) (UC) | 280 V (50 / 60 Hz) |
| Nominal discharge current (8/20 µs) (In) | 10 kA |
| Max. discharge current (8/20 µs) (Imax) | 20 kA |
| Voltage protection level (UP) | ≤ 1.5 kV |
| Response time (tA) | ≤ 100 ns |
| Max. mains-side overcurrent protection | not required |
| Rated breaking capacity of the internal backup protection | 25 kA |
| Short-circuit withstand capability (ISCCR) | 25 kArms |
| Temporary overvoltage (UT) – characteristic | 440 V / 120 min. – withstand |
| Indication of disconnector | red indicator |
| Number of ports | 1 |
| Operating temperature range (TU) | -40 °C ... +80 °C |
| For mounting on | NH fuse holder, size 00 |
| Enclosure material | Thermoplastic, red, UL 94 V-0 |
| Place of installation | Indoor |
| Degree of protection | IPX4W |
1-pole surge arrester with high-power
Varistor and a spark gap - series
for use in NH fuse holders, size 00
SPD Type 2 according to EN 61643-11
Fault indication by tripping indicator,
maximum continuous operating voltage: 280 V ac
Protection level: <1.5 kV
Nominal discharge current: 10 kA (8/20)
Max. Discharge current: 20 kA (8/20)
Energy coordination according to DIN EN 62305-4 (VDE 0185-
305-4) with type 1 and type 3 arrester the Red / Line family
Mounting on NH fuse bases size 00;
Type: VA NH00 280 Sale Unit: 1 ST.