Further information for DEHN 819137 HVI P LO 90 27 L100M SW lightning protection cable 100 m
General
Product type
high-voltage resistant insulated derivation
Manufacturer
DEHN
Colour
Black
Separation distance in air
90 cm
Separation distance from solid building material
180 cm
Norm
DIN EN 62305-3 (VDE 0185-305-3)
Model
for on-site assembly
Material of conductor
Cu
Material of insulation
PE
Sheath material
PE
Colour of conductor
black ●
Diameter Ø conductor
27 mm
Standard
DIN EN IEC 62561-8 (VDE 0185-561-8)
Special sheath
The DEHN HVI P LO 90 27 L100M SW is a high-voltage-resistant insulated conductor (HVI-power-long cable) specifically developed for use in lightning protection systems. It is used to maintain the required separation distance between parts of the external lightning protection and internal electrically conductive components such as electrical installations, pipe systems or metal structures. This distance is required according to DIN EN 62305-3 (VDE 0185-305-3) to prevent dangerous flashovers during lightning discharges. The cable is designed for on-site cutting and is supplied in a fixed length of 100 meters, with the color being black.
Applications
The HVI-power-long cable is used in lightning protection technology, particularly in buildings equipped with an external lightning protection system. It is installed where metallic conduits or electrical installations run close to lightning conductors or grounding cables. The cable ensures that no dangerous discharges occur between different conductive parts during a lightning strike by electrically simulating a defined, safety-relevant separation distance. This is especially important in buildings with complex pipe or electrical installations.
Functions and Equipment in Detail
The cable features an outer special jacket specifically developed for diverting high lightning impulse voltages. This jacket enables the energy of a lightning strike to be directed to a reference potential without causing sliding discharges. The cable's construction ensures that electrical voltage during a lightning event is controlled and dissipated, minimizing the risk of spark flashovers or thermal damage. The cable is designed for use in air and on solid building materials, with an equivalent separation distance of 90 cm in air and 180 cm on solid building materials.
Technology Explained Simply
The HVI-power-long cable operates on the principle of high-voltage resistance. The special jacket is dimensioned so that it does not break down under high impulse voltages, such as those occurring during a lightning strike, but instead safely diverts the energy. This simulates a secure electrical separation distance without requiring a large physical gap between the conductors. Thus, the cable is a technical solution to meet the requirements of DIN EN 62305-3 without additional construction work. The insulation is designed to remain stable even under high energy impacts.
Compatibility and Accessories
The cable is designed for use in lightning protection systems and can be combined with other components of the DEHN lightning protection system. It is intended for on-site cutting, meaning it is integrated into the respective installation and connected to the required points on-site. The cable is used in conjunction with grounding cables, lightning conductors, or other metallic components present in the building.
Installation and Mounting
Installation is carried out on-site, with the cable being mounted according to the requirements of the lightning protection standard DIN EN 62305-3. The cable is fixed at points where a secure separation distance between the lightning protection system and other conductive parts must be ensured. Mounting is typically done using suitable brackets or directly onto components, ensuring the electrical insulation of the special jacket remains intact. The 100-meter length allows for flexible adaptation to the specific installation situation.
Operational Advantages
The HVI-power-long cable provides a reliable and standard-compliant solution for maintaining the separation distance in lightning protection systems. It reduces the risk of flashovers and sliding discharges, increasing the safety of buildings and the installations within them. The cable is easy to install and requires no additional construction measures, as it replaces physical distance with electrical insulation. The use of HVI-power-long cables contributes to reducing damage during lightning events and supports compliance with legal and technical requirements in lightning protection.