| General |
| Product type | earthing and short-circuit set |
| Model | partially insulated (TI) |
| Connection thread | M10 |
| Application range | NS cable distributor (KVS) |
| Norm | DIN VDE 0683-100 (EN/IEC 61230) |
| Variant No. of EaS device | VUKMT58 |
| Dimensions | 440 x 330 x 66 mm |
| Shipping packaging | steel sheet case |
| Variant number | VUKMT58 |
The DEHN earthing and short-circuiting set TI 2F KVS SBK, type EKS TI 2F KVS SBK, is a three-pole set for safe earthing and short-circuiting of electrical installations at the worksite. It is specifically designed for use with NS cable distributors (KVS) and complies with the requirements of DIN VDE 0683-100 (EN/IEC 61230) and DIN VDE 0105-100 (EN 50110). The set is delivered in a steel sheet case, which ensures protection and proper storage of the components. The execution is partially insulated (TI), meaning that the earthing and short-circuiting conductors are insulated at the ends to enable safe handling and prevent short circuits. The connection threads have a diameter of M10, enabling universal use at standard connection points.
Applications
This earthing and short-circuiting set is intended for use in electrical installations, particularly during maintenance and repair work on NS cable distributors. It is used to safely earth and short-circuit the parts of the installation being worked on, minimizing the risk of electric shock for workers. The application follows the regulations of DIN VDE 0105-100, which govern safety measures for maintaining electrical installations. Therefore, using this set is an integral part of safety measures in the electrical field.
Functions and Equipment in Detail
The set includes all necessary components for safe earthing and short-circuiting at a cable distributor. The partially insulated (TI) design ensures that the conductors are insulated at the ends, reducing the risk of unintended short circuits or electrical contact. The M10 connection threads allow for secure and standardized attachment to the corresponding connection points. The earthing and short-circuiting conductors are designed for use in electrical installations and meet the technical requirements of the mentioned standards.
Technology Explained Simply
The partially insulated (TI) design means that the conductors are insulated at the ends where they are connected, while the rest of the conductor remains conductive. This enables safe installation, as the insulation prevents the conductor from accidentally contacting other conductors or metallic parts. Earthing is achieved by connecting to an earthing point, ensuring electrical equipotential bonding. Short-circuiting serves to bring the voltage at the worksite to zero by connecting the phase conductors to each other and to the earthing point. Thus, the set is a tool for ensuring electrical safety when working on live parts.
Compatibility and Accessories
The set is specifically designed for NS cable distributors (KVS) and can be used directly there. The variant number of the EuK device is VUKMT58. Other rope lengths can be selected via the EuK configurator on the website www.dehn.de/de/euk, enabling adaptation to specific requirements.
Installation and Mounting
Installation is carried out by screwing the earthing and short-circuiting conductors onto the corresponding connection points of the cable distributor using the M10 threads. The conductors are arranged to safely connect the phase conductors and the protective conductor. Installation must follow the regulations of DIN VDE 0105-100, with earthing and short-circuiting to be performed before work begins. Removal of the conductors is only permitted after work is completed and it has been confirmed that the installation can be operated safely again.
Operational Advantages
The set provides a reliable and standardized solution for earthing and short-circuiting at NS cable distributors. The partially insulated design increases safety during handling, and the M10 connections ensure secure fastening. Using the set contributes to compliance with safety regulations and protects workers from electrical hazards. Delivery in a steel sheet case ensures proper storage and protects the components from damage.