DEHN 563200 PAS 11AK Potential Equalization Bar

UPS > Accessories

DEHN 563200 PAS 11AK Potential Equalization Bar

Lieske Part No. 227983
Mfg Part No 563200
EAN-Code 4013364056558
Manufacturer DEHN
Here only 35,53 EUR
42,28 EUR incl. VAT

Further information for DEHN 563200 PAS 11AK Potential Equalization Bar

General
NormDIN EN 62561-1 -
ApplicationProtective and functional equipotential bonding -
Cover capPlastic, grey, halogen-free -
CoverSealed -
ModelStandard -
Material of contact railCu /gal Sn
Cross section30 mm²
Fixing[2x] 6 x 8 mm
StandardEN 62561-1
The DEHN PAS 11AK is a potential equalisation bar designed in accordance with DIN EN 62561-1 and intended for protective and functional potential equalisation in accordance with DIN VDE 0100-410/540 as well as for lightning protection potential equalisation in accordance with DIN EN 62305-3 (VDE 0185-305-3). As a main earthing bar, it serves to connect protective conductors, functional conductors and lightning protection conductors, thereby minimising voltage differences in the electrical system and ensuring the safety of personnel and installations. The bar is available in standard configuration and has been tested in accordance with DIN VDE 0618-1, confirming compliance with the required electrical and mechanical specifications.

Potential equalisation bar is used here as a central component in the earthing system to prevent potential voltage differences between various conductors and metallic parts. This is particularly important in buildings with complex electrical and IT systems, where uncontrolled potential equalisation can lead to disturbances, damage or hazards. The bar serves as a collection point for all conductors to be earthed and enables an orderly and safe connection.

Protective and functional potential equalisation is achieved by connecting protective conductors (PE) and functional conductors (e.g. for data transmission or signal processing) to the bar. This ensures that all metallic parts of an electrical system are at the same potential, reducing the risk of touch voltages and disturbances. The bar is thus an essential component of electrical installation safety.

Lightning protection potential equalisation is enabled by integrating the bar into the lightning protection system. During a lightning strike, high voltage surges can occur, which may enter the building via conductors. The PAS 11AK ensures that these voltages are discharged through the earthing system, thereby minimising the risk of overvoltages in electrical installations and IT systems. The standard DIN EN 62305-3 specifies the requirements for lightning protection measures, which the bar fulfils.

The bar features push-on terminals made of steel, galvanised, which enable a secure and durable connection of the conductors. The mounting blocks and the cover are made of halogen-free plastic in grey colour, allowing use in rooms with special requirements for fire behaviour and environmental compatibility. The cover is tamper-proof, preventing unauthorised manipulation, and is labelable, enabling clear identification of the bar’s function and assignment within the system.

The tested configuration in accordance with DIN VDE 0618-1 ensures the reliability of the bar under real operating conditions. The testing includes, among other things, electrical conductivity, mechanical strength and corrosion resistance of the components. This guarantees that the bar performs its function even under long-term load and in different environments.

The bar is designed for use in electrical installations, particularly in buildings with increased safety requirements, such as industrial facilities, office buildings, hospitals or data centres. It is part of the earthing and potential equalisation system and is typically installed in a distribution box or main distribution. Mounting is done via the mounting blocks, which allow secure and stable attachment to a wall or enclosure.

The cover protects the terminals and connections from mechanical damage, dust and moisture. The tamper-proof design prevents unauthorised access, which is particularly important in public or protected areas. The labelling option enables clear identification of the bar within the system, facilitating maintenance and inspection.

The bar is designed for use in electrical installations complying with the standards DIN VDE 0100-410/540 and DIN EN 62305-3. It is therefore capable of meeting the requirements for protective and functional potential equalisation as well as lightning protection potential equalisation. Use in other systems is only possible if the respective standards and regulations permit it.

Installation is carried out by securing the bar to a suitable wall or enclosure surface using the supplied mounting blocks. The terminals are connected to the respective conductors via the push-on terminals. The cover is then mounted, with the tamper-proof feature ensuring that the bar cannot be opened after installation without authorised measures. Labelling is done directly on the cover to clearly indicate the bar’s function and assignment within the system.

The bar is available in standard configuration and has been tested in accordance with DIN VDE 0618-1. Use in electrical installations requires compliance with applicable standards and regulations. The bar is not a substitute for a complete earthing system, but a component of it. Installation must be carried out by qualified personnel to ensure safety and functionality.

The halogen-free plastic cover ensures better fire behaviour and reduces the formation of toxic smoke gases in the event of fire. This is particularly important in rooms with increased fire protection requirements. The grey colour of the cover is neutral and fits into most installation environments.

The tamper-proof cover enables secure and controlled installation. The tamper-proof feature prevents unauthorised access and ensures that the bar can only be opened by authorised personnel. This is particularly important in public or protected areas to ensure the integrity of the installation.

The labelable cover allows for clear identification of the bar within the system. This facilitates maintenance, inspection and fault diagnosis, as the function and assignment of the bar are immediately recognisable. Labelling can be done with a pen or label, depending on requirements.

The bar is designed for use in electrical installations complying with the standards DIN VDE 0100-410/540 and DIN EN 62305-3. It is therefore capable of meeting the requirements for protective and functional potential equalisation as well as lightning protection potential equalisation. Use in other systems is only possible if the respective standards and regulations permit it.

Installation is carried out by securing the bar to a suitable wall or enclosure surface using the supplied mounting blocks. The terminals are connected to the respective conductors via the push-on terminals. The cover is then mounted, with the tamper-proof feature ensuring that the bar cannot be opened after installation without authorised measures. Labelling is done directly on the cover to clearly indicate the bar’s function and assignment within the system.

The bar is available in standard configuration and has been tested in accordance with DIN VDE 0618-1. Use in electrical installations requires compliance with applicable standards and regulations. The bar is not a substitute for a complete earthing system, but a component of it. Installation must be carried out by qualified personnel to ensure safety and functionality.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/227983
qrcode für DEHN 563200 PAS 11AK Potential Equalization Bar