| General |
| Operating voltage mains side | 230 V |
| Input frequency | 50 Hz |
| Nominal current | 0,4 A |
| Operating voltage telecommunication side | 30? 50 V |
| Frequency telecommunication side | 23? 54 Hz |
| Impedance | 8 kOhm < Z < 29 kOhm |
| Lightning impulse | 3 to 8 flashes/second |
| Flash energy | max. 20 Ws |
| Loudness | > 100 dB (A) |
| Application class | HUF |
| Degree of protection | Class II |
| Colour housing | White |
| Actuator colour | Grey |
| BZT-No. | D 130 148 H |
The Crack-IT doorbell with flash, type 1-601.13.1.51, is an electronic signaling device for acoustic and optical announcement of telephone calls. It is intended for signaling in environments with high sound levels or for individuals with hearing impairments, where conventional doorbell tones are insufficient. The device combines a loud tone alert with a flashing light function, both of which can be activated or deactivated independently. Installation is carried out via connection cables for the telephone network and 230 V mains voltage, enabling simple installation without additional components.
Applications
This device is designed for indoor use where high sound volume or visual signaling is required. Typical applications include office buildings, workshops, nursing and care homes, as well as apartments with large room volumes. The visual signaling via flashing light is particularly suitable for hearing-impaired individuals, while the high sound volume ensures that calls are not missed in noisy environments. The application class HUF according to DIN 40 040 confirms suitability for use in public and commercial spaces.
Functions and Equipment in Detail
The doorbell offers three different tone colors, which can be adjusted continuously in volume. The sound level exceeds 100 dB (A), measured in a small room, ensuring clear perception even in larger spaces. Visual signaling is provided by a flashing function with a flash rate of 3 to 8 flashes per second, which is also adjustable. The flash energy reaches a maximum of 20 Ws, providing high light output. The light guidance is indirect and diffused to achieve even illumination and avoid glare. The functions can be activated individually or combined (flash and acoustic).
Technology Explained Simply
The device features an integrated power supply that accepts 230 V mains voltage and provides power. The interface to the telephone network is designed for an operating voltage of 30 to 50 V and 23 to 54 Hz, ensuring compatibility with conventional telephone systems. The impedance ranges between 8 kOhm and 29 kOhm, enabling adaptation to the telephone line. Protection class II (double insulated) means the device can operate without a protective earth conductor and features double or reinforced insulation, ensuring safe use indoors. The housing is white, the controls are gray, allowing unobtrusive integration into various indoor environments.
Compatibility and Accessories
The doorbell is designed for use with conventional telephone systems that meet the specified interface requirements.
Installation and Mounting
Installation is carried out using the supplied connection cables. The device is connected to the telephone line and powered via the 230 V mains. Mounting requires no special tools or additional components. Positioning should be at a visible location to optimally utilize the visual signaling. Volume, tone color, and flash rate settings are adjusted using the controls on the device.
Operational Advantages
The combination of acoustic and optical signaling allows flexible adaptation to different environments and needs. The continuous volume control and adjustable flash rate offer individual settings. The high sound volume and light output ensure reliable perception of incoming calls. Simple mounting and integrated power supply reduce installation effort. The device is designed for indoor use and meets the requirements of application class HUF according to DIN 40 040.
Protection Class and Safety
Protection class II (double insulated) ensures safe operation without a protective earth conductor. The operating voltage of 230 V/50 Hz is suitable for standard household power supply in Germany. The rated current consumption is 0.4 A during operation.
Housing and Design
The housing is white, the controls are gray, providing a neutral and unobtrusive appearance. The indirect and diffused light guidance ensures even illumination without glare.
Functions
- Acoustic signaling with three adjustable tone colors
- Continuous volume control exceeding 100 dB (A)
- Visual signaling via flash with adjustable rate (3–8 flashes/second)
- Flash energy max. 20 Ws
- Integrated power supply for 230 V/50 Hz
- Interface for telephone network (30–50 V, 23–54 Hz)
- Protection class II (double insulated)
- Application class HUF according to DIN 40 040
- Housing white, controls gray
- Connection cables for telephone and mains included
Applications
- Indoor spaces with high sound levels
- Apartments, offices, workshops
- For hearing-impaired individuals
- Commercial and public spaces
Installation
- Connection to telephone line and 230 V mains
- No additional tools or components required
- Settings adjusted via controls on the device
Safety
- No information provided regarding weather resistance or moisture resistance
- Not intended for outdoor use
Compatibility
- Compatible with telephone systems meeting the specified interface requirements
- No specific accessories or additional components mentioned