| General |
| Degree of protection | IP 40 |
| Over voltage category | CAT III 600 V, CAT IV 300 V |
| Voltage measurement range | 600 V |
| Current measurement range | 10 A |
| Resistance measurement range | 40 MΩ |
| Temperature measuring range | 500 °C |
| Capacitance measurement range | 100 µF |
| Measuring range for frequency | 5 MHz |
| Measurement functions | AC/DC voltage, AC/DC current, resistance, temperature, capacitance, frequency, continuity test, diode test |
| Indication | large LCD display with display backlighting |
| Functions | automatic range selection, Data Hold |
| Standards | EN61010-1, EN6110-2-033, EN61010-031 |
| Scope of delivery | batteries included |
The digital multimeter 111404 from Cimco is a professional measuring instrument for use in electrical engineering and industrial environments. It features automatic range selection, enabling fast and reliable measurements without manual adjustment. The device is designed for measuring AC and DC voltages up to 600 V as well as AC and DC current values up to 10 A. Additionally, resistances up to 40 MΩ, temperatures up to 500 °C, capacitances up to 100 µF, and frequencies up to 5 MHz can be measured. The overvoltage category CAT III 600 V and CAT IV 300 V makes the multimeter suitable for use in electrical installations that meet these safety requirements. The measurement functions include optical and acoustic continuity testing as well as a diode test, allowing the functionality of electrical components to be checked. The large LCD display with backlighting ensures good readability even in poor lighting conditions. The Data Hold function allows a measured value to be held, for example, to document a measurement in hard-to-reach areas. The device is tested according to the standards EN61010-1, EN6110-2-033, and EN61010-031, which underscores the safety and reliability of the device. The protection rating IP 40 protects against solid foreign objects larger than 1 mm and against splashing water from any direction, making the multimeter suitable for indoor use. Batteries are included in the delivery scope, so the device is ready to operate immediately after unpacking.
Applications
The multimeter 111404 is suitable for a wide range of applications in the field of electrical engineering, including maintenance and servicing of electrical installations, testing of electrical components, and diagnosing faults in power supply networks. The high overvoltage category allows use in industrial and commercial environments where high electrical voltages occur. The temperature measurement function extends the application range to monitoring heating elements, transformers, or other thermally stressed components. Capacitance and frequency measurement are useful for testing capacitors and electronic circuits.
Functions and Equipment in Detail
The automatic range selection reduces the risk of errors during measurement, as the device automatically detects and displays the appropriate measurement range. The measurement of AC and DC voltages up to 600 V and current values up to 10 A covers most requirements in industrial and commercial applications. Resistance measurement up to 40 MΩ enables testing of insulation resistance and other high resistances. Temperature measurement up to 500 °C allows monitoring of hot components, with measurement carried out via a suitable temperature sensor. Capacitance measurement up to 100 µF and frequency measurement up to 5 MHz extend functionality for electronic applications. The optical and acoustic continuity test helps identify short circuits or breaks in wiring. The diode test enables checking the forward direction of diodes. The large LCD display with backlighting ensures clear presentation of measurement values, even in poorly lit environments. The Data Hold function holds the current measurement value on the display, which is helpful for documenting measurement results.
Technology Explained Simply
The automatic range selection ensures that the multimeter automatically selects the correct measurement range without the user having to manually switch between different settings. This reduces the likelihood of incorrect settings and increases measurement accuracy. The overvoltage category CAT III 600 V and CAT IV 300 V refers to safety requirements for measuring instruments in electrical installations. CAT III applies to installations with a nominal voltage up to 600 V, CAT IV to installations up to 300 V, with CAT IV representing the highest safety level. The protection rating IP 40 means the device is protected against solid foreign objects larger than 1 mm and against splashing water from any direction. The standards EN61010-1, EN6110-2-033, and EN61010-031 define safety and performance requirements for electrical measuring instruments. The display backlighting enables readability of the display even in dark environments. The Data Hold function holds the last measured value on the display, which is useful for documenting measurement values.
Compatibility and Accessories
Temperature measurement is performed via an external temperature sensor connected to the device.
Mounting and Installation
The multimeter 111404 is designed as a handheld device and requires no mounting or installation. It is simply picked up and connected to the electrical wires or components to be measured. Operation is via buttons on the device, with functions accessible through a clear user interface. The display shows the measurement values directly, with the backlighting activatable as needed. Batteries are included in the delivery scope, so the device is immediately ready for operation. No additional tools or mounting aids are required.
Operational Advantages
The multimeter 111404 offers high measurement accuracy and reliability through automatic range selection and high overvoltage category. The wide range of measurement functions – voltage, current, resistance, temperature, capacitance, frequency – enables comprehensive diagnosis of electrical systems. The optical and acoustic continuity test as well as the diode test facilitate testing of electrical components. The large LCD display with backlighting ensures good readability, even in poorly lit environments. The Data Hold function enables documentation of measurement values. Compliance with the standards EN61010-1, EN6110-2-033, and EN61010-031 ensures the safety of the device.