| General |
| Rated voltage | 500 V |
| Switching capacity | 10 kA |
These replacement fuses from Chauvin Arnoux are specifically designed for the measuring instrument types C.A 5005 and C.A 5011. They serve as protective components in the electrical system of the devices and prevent damage caused by overcurrents or short circuits. The fuses are designed as high-performance fuses and provide reliable protection in safety-critical applications. With a rated current of 1 A and a
superfast tripping characteristic, they respond quickly to current overloads, thereby protecting the integrated electronic components. The
rated voltage is 500 V, enabling use in systems with corresponding voltage levels. The
breaking capacity of 10 kA ensures that the fuses can safely and completely interrupt even high short-circuit currents without failing.
Applications
These fuses are exclusively intended for the specified measuring instruments C.A 5005 and C.A 5011. They integrate into the internal power supply or protection circuits of these devices and ensure their operational safety. Use in other devices or systems is not intended and may lead to malfunctions or damage. The fuses are suitable for use in electrical systems with voltages up to 500 V and offer a high level of protection.
Functions and Equipment in Detail
The fuses feature a
superfast tripping characteristic, meaning they respond quickly even to slight overloads above the rated current. This is particularly important to protect sensitive electronic components from thermal stress. The
dimensions of 6 x 32 mm correspond to the standard size for small fuses and allow for easy installation in the designated holders of the measuring instruments. The fuses are supplied in a set of 10 pieces, making them suitable for maintenance work or as a spare stock.
Technology Explained Simply
The
superfast tripping characteristic means that the fuse interrupts within seconds at approximately 1.1 times the rated current. This is significantly faster than standard fuses and protects sensitive electronics. The
breaking capacity of 10 kA indicates the maximum current the fuse can safely interrupt without being destroyed. The
rated voltage of 500 V defines the maximum operating voltage at which the fuse functions reliably. The
dimensions of 6 x 32 mm are a common format used in many measuring instruments and small electronic devices.
Compatibility and Accessories
The fuses are exclusively compatible with the measuring instrument types C.A 5005 and C.A 5011. Use in other devices is not intended and may cause malfunctions. The fuses are designed as replacement parts and replace the original fuses installed in the device.
Installation and Mounting
Installation is carried out by inserting the fuse into the designated fuse holder inside the measuring instrument. The dimensions of 6 x 32 mm allow for easy handling and interchangeability. No additional tools or mounting aids are required. The fuses are ready for immediate use once inserted into the holder.
Operational Advantages
The fuses provide fast and reliable protection for the measuring instruments C.A 5005 and C.A 5011. The
superfast tripping characteristic minimizes the risk of damage to sensitive components. The
breaking capacity of 10 kA ensures safe interruption even under high short-circuit currents. The compact size of 6 x 32 mm enables easy replacement and efficient maintenance. The set of 10 pieces ensures sufficient stock for regular maintenance tasks.
The fuses are designed as replacement parts for the specified devices and replace the original fuses installed in the device. Use in other applications is not intended. The product is delivered in a set of 10 fuses, all of which have identical technical specifications.