| General |
| Degree of protection | PVC |
| Connector type | Straight plug Ø 4 mm |
| Connector arrangement | axial socket |
| Current carrying capacity | 20 A |
| Operating voltage | 600 V |
| Safety category | CAT III |
| Number of cables | 2 |
| Colours | red, black |
These test leads from Chauvin Arnoux are designed for use in electrical and measurement technology. They are standard test leads made of PVC, supplied as a set with two cables – one red and one black – each equipped with straight 4 mm connectors. The connectors are insulated and feature an axial socket, enabling a secure and rearward connection. The leads are rated for an operating voltage of 600 V in category CAT III, making them suitable for measurements in electrical installations with voltages up to 600 V and a specific overvoltage protection level. The maximum current rating is 20 A, and the length of each lead is 2 m. The cables are designed for general applications in the trade and offer a balanced combination of performance and cost-effectiveness.
Applications
These test leads are suitable for use in electrical installations where measurements are performed with a multimeter, oscilloscope, or other measuring instruments. The CAT III 600 V category makes them suitable for measurements on distributors, enclosures, and other installations under voltage. The 2 m length provides sufficient reach for work without the leads becoming too long and unwieldy. The colour coding (red and black) facilitates distinction between positive and negative poles, which is helpful during wiring and when interpreting measurement results.
Functions and Equipment in Detail
The leads are equipped with straight 4 mm connectors integrated into an axial socket. This design enables a secure and stable connection to measuring instruments and test objects. The insulation of the connectors protects against unintended contact and increases safety during work. The PVC insulation of the cables themselves provides good protection against mechanical damage and is suitable for indoor use. The cables are rated for a maximum current of 20 A, which is sufficient for typical use in electrical trade practice.
Technology Explained Simply
The designation CAT III 600 V refers to the safety category of the test leads. CAT III indicates a specific overvoltage protection level intended for measurements on distributors and enclosures. The 600 V voltage is the maximum operating voltage that the leads can safely transmit. The 20 A current rating is the maximum load the leads can carry without overheating or damage. The 2 m length provides sufficient reach without the leads becoming too long and unwieldy. The PVC insulation offers good protection against mechanical damage and is suitable for indoor use.
Compatibility and Accessories
The test leads are compatible with measuring instruments that support a 4 mm socket connection, such as multimeters, oscilloscopes, or other measuring devices. The axial socket enables a secure connection to the devices. The colour coding (red and black) facilitates polarity identification.
Installation and Mounting
The installation of the test leads involves simply inserting the connectors into the corresponding sockets of the measuring instruments and test objects. The axial sockets enable a secure and stable connection. The leads are flexible and can be easily bent and positioned without damaging the insulation. The PVC insulation provides good protection against mechanical damage.
Operational Advantages
The test leads provide a reliable and safe connection between measuring instrument and test object. The insulation of the connectors increases safety during work. The colour coding facilitates polarity identification. The 2 m length provides sufficient freedom of movement. The CAT III 600 V category makes the leads suitable for use in electrical installations. The 20 A current rating is sufficient for typical use. The PVC insulation provides good protection against mechanical damage.