Chauvin Arnoux P01102197, EAN: 3663653008464

Chauvin Arnoux P01102197 transponder reader

Chauvin Arnoux P01102197 transponder reader

Lieske Part No. 1142415
Mfg Part No P01102197
EAN-Code 3663653008464
Manufacturer Chauvin Arnoux
Here only 691,92 EUR
823,38 EUR incl. VAT

Further information for Chauvin Arnoux P01102197 transponder reader

Eigenschaften
AC / AC ramp40 - 5 350 V
Resolution / accuracy10 V / ±1 % L
Maximum current200 mA
Measurement of I range / accuracy100 mA / 200 mA ±2 % L
Test voltage100 V / 250 V / 500 V / 1 000 V
Inductance range / resolution / accuracy15 mH / ±10 % L
Impulse testx 0,5; x 1; x 2; x 4; x 5; x 10 (DC) IΔ;n
Isolation current resolution / accuracy0,1 mA; -0% +(7% L + 2 mA)
Voltage and frequency of installation190,0 - 440,0 V; 45-55 Hz
Measurement range / accuracy40 A / ±2,5 % L
Dimensions / weight407 x 341 x 205 mm; 16 kg
The CA 6163 from Chauvin Arnoux is a professional installation tester for electrical safety testing of devices, machines and enclosures. It is particularly used for conformity testing in the context of final inspection, recurring tests, as well as maintenance and repair work. The device is designed for use in industrial electrical engineering, by electricians, maintenance companies, customer service firms and testing facilities. It enables comprehensive testing according to international standards and supports the certification of electrical equipment.

Applications

The CA 6163 is primarily used in industrial electrical engineering, where electrical safety of machines and enclosures must be proven. It is suitable for manufacturers of electrical devices who must demonstrate CE marking, as well as for testing facilities conducting recurring inspections. It is also used in technical training centres for training skilled personnel. The tests include final inspection, maintenance work and compliance checks of machine fleets.

Functions and Equipment in Detail

The device features a touch colour display with a resolution of 800 x 480 pixels and a diagonal of 5 inches. The user interface is multilingual and includes help screens with text, symbols and images to guide the user through the testing processes. Four express command buttons allow quick access to functions such as printing test results, calling up help, returning to the main screen or the previous menu. Tests can be automated and documented via an integrated RFID reader, barcode scanner or label printer.

Technology Explained Simply

The CA 6163 offers a wide range of measurement functions, including continuity testing with 2- or 4-wire measurement, insulation testing up to 50 GΩ, and testing of residual current devices (RCDs) of types A, AC, B, B+, F and EV. Loop impedance (Zs) measurement is performed both without disconnection and in high-current mode, with a display range for short-circuit current (Ik) up to 20 kA. Earth leakage current measurement is carried out directly, differentially or by substitution, with contact leakage current at sockets and stands measurable up to 30 mA. Phase sequence testing and discharge time determination are also integrated. The test voltage can be set in steps of 100 V, 250 V, 500 V and 1000 V. Mains voltage measurement is performed in the range of 190.0 to 440.0 V at a frequency of 45 to 55 Hz.

Compatibility and Accessories

The device is equipped with interfaces for external devices, including connections for HV test guns, a barcode scanner, an RFID reader, a label printer and a START/STOP pedal. It supports communication via WLAN as well as via a USB-B port for connection to a PC and two USB-A ports for external devices. Suitable accessories include Kelvin crocodile clips, test probes, cables, HV test guns, a CEE adapter, crocodile clips CAT IV-1000 V, test probes with 4 mm socket CAT IV and CAT III 1000 V, and a transport case. The test guns are available with cables of 3 m and 15 m.

Installation and Mounting

The CA 6163 is delivered in a yellow construction case and is designed for use in industrial environments. Operation is via the touchscreen, which can also be operated with gloves. Power supply is via 230 VAC ±10%. The devices are designed for use in electrical installations complying with standards IEC/EN 60204-1, IEC/EN 61439-1, IEC/EN 60335-1, IEC/EN 62368-1, IEC/EN 60598-1 and IEC/EN 60974-4. Testing is carried out according to standards IEC 61557-1 to -16 (partially). The safety requirements of standards IEC/EN 61010-031 and IEC/EN 61180 for high-voltage testing are met, including two-hand operation, optical indication of high voltage and automatic discharge of the test object after testing.

Operational Advantages

The CA 6163 can store up to 100,000 tests and enables data transfer via WLAN or USB to a PC. The PC software is used for analysis and reporting. Software updates are conveniently performed via a USB stick. Integrated functions such as automatic test sequences, Pass/Fail label printing and support for RFID and barcode scanners increase the efficiency and accuracy of testing. The devices are designed for use in industrial electrical engineering and offer high reliability in performing safety tests. The operating temperature ranges from 0 to +45 °C, and the storage temperature ranges from -30 to +60 °C. The device has a protection rating of IP 64 (closed) and IK 08, making it suitable for use in harsh environments. Electrical safety complies with standards IEC 61010-1, IEC 61010-2-030, IEC 61010-2-034 and IEC 61010-2-032. The electrical safety category includes 300 V CAT II, 300 V CAT III and 600 V CAT III.

Functions and Equipment in Detail

The device offers a wide range of measurement functions, including continuity testing with 2- or 4-wire measurement, insulation testing up to 50 GΩ, and testing of residual current devices (RCDs) of types A, AC, B, B+, F and EV. Loop impedance (Zs) measurement is performed both without disconnection and in high-current mode, with a display range for short-circuit current (Ik) up to 20 kA. Earth leakage current measurement is carried out directly, differentially or by substitution, with contact leakage current at sockets and stands measurable up to 30 mA. Phase sequence testing and discharge time determination are also integrated. The test voltage can be set in steps of 100 V, 250 V, 500 V and 1000 V. Mains voltage measurement is performed in the range of 190.0 to 440.0 V at a frequency of 45 to 55 Hz.

Compatibility and Accessories

The device is equipped with interfaces for external devices, including connections for HV test guns, a barcode scanner, an RFID reader, a label printer and a START/STOP pedal. It supports communication via WLAN as well as via a USB-B port for connection to a PC and two USB-A ports for external devices. Suitable accessories include Kelvin crocodile clips, test probes, cables, HV test guns, a CEE adapter, crocodile clips CAT IV-1000 V, test probes with 4 mm socket CAT IV and CAT III 1000 V, and a transport case. The test guns are available with cables of 3 m and 15 m.

Installation and Mounting

The CA 6163 is delivered in a yellow construction case and is designed for use in industrial environments. Operation is via the touchscreen, which can also be operated with gloves. Power supply is via 230 VAC ±10%. The devices are designed for use in electrical installations complying with standards IEC/EN 60204-1, IEC/EN 61439-1, IEC/EN 60335-1, IEC/EN 62368-1, IEC/EN 60598-1 and IEC/EN 60974-4. Testing is carried out according to standards IEC 61557-1 to -16 (partially). The safety requirements of standards IEC/EN 61010-031 and IEC/EN 61180 for high-voltage testing are met, including two-hand operation, optical indication of high voltage and automatic discharge of the test object after testing.

Operational Advantages

The CA 6163 can store up to 100,000 tests and enables data transfer via WLAN or USB to a PC. The PC software is used for analysis and reporting. Software updates are conveniently performed via a USB stick. Integrated functions such as automatic test sequences, Pass/Fail label printing and support for RFID and barcode scanners increase the efficiency and accuracy of testing. The devices are designed for use in industrial electrical engineering and offer high reliability in performing safety tests. The operating temperature ranges from 0 to +45 °C, and the storage temperature ranges from -30 to +60 °C. The device has a protection rating of IP 64 (closed) and IK 08, making it suitable for use in harsh environments. Electrical safety complies with standards IEC 61010-1, IEC 61010-2-030, IEC 61010-2-034 and IEC 61010-2-032. The electrical safety category includes 300 V CAT II, 300 V CAT III and 600 V CAT III.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1142415
qrcode für Chauvin Arnoux P01102197 transponder reader