• Differential voltage probe as an accessory for analog or digital oscilloscopes
• For displaying signals without a ground reference
• Designed as a laboratory housing for standalone use or mechanically attached to MTX oscilloscopes
• 2 differential channels with coaxial connectors for use with oscilloscope probes
• 2 x 30 MHz bandwidth
• Suitable for Class 1 oscilloscopes

Description:


The MTX 1032-B and MTX 1032-C differential voltage probes are high-quality accessories for analog and digital oscilloscopes, enabling the display of signals without a ground reference. Their independent design in a laboratory housing allows standalone use, with the option to attach them mechanically to MTX oscilloscopes. The MTX 1032-C features a 50 MHz bandwidth and meets 600 V CAT II requirements, while the MTX 1032-B has a 30 MHz bandwidth and is rated for 600 V CAT III. Both models come with differential inputs and coaxial connectors, supporting versatile use with different connector types.

Common technical specifications include an input voltage range of ±0.1V to ±400V, mains power supply, and adherence to safety standards per IEC 61010-1. The probes are EMC-compliant according to NF EN 61326-1. With dimensions of 270 x 250 x 63 mm and a weight of 1.2 kg, these probes are compact and easy to integrate.

Technical Details:


  • Models:
  • - MTX 1032-B: 30 MHz, 600 V CAT III, banana plugs
    - MTX 1032-C: 50 MHz, 600 V CAT II, coaxial and banana connectors
  • Inputs: 2 differential inputs / coaxial connectors
  • Differential voltage range: ± 0.1V to ± 400 V
  • Power supply: Mains
  • Safety standards: IEC 61010-1
  • EMC standards: NF EN 61326-1 + A1 + A2
  • Dimensions: 270 x 250 x 63 mm
  • Weight: 1.2 kg

Included Items:


  • MTX 1032-B or MTX 1032-C differential voltage probe
  • Power supply
  • Documentation