| General |
| Simulation | 1- or 3-phase networks 230 V |
| Output voltage | mains voltage ±15 % |
| Amperage | 1, 2, 5, 10, 20 A ±10% |
| Phase shift | 30°, 45°, 60° ±5° inductive or capacitive |
| Harmonic content | Harmonic content, 15, 25 % and variable |
| Current supply | 230 V via protective earth plug |
| Safety standard | IEC 61010 300 V CAT II |
| Warning light | With applied voltage - |
| Input filter | Yes - |
| Fuses | slow-acting - |
| Scope of delivery | Device in robust portable case - |
The training device from Chauvin Arnoux, type 01NC5003, is a
didactic aid for safe simulation of electrical networks and three-phase loads. It is used for training and education in the field of electrical engineering, particularly for practical instruction in measurement and analysis methods in power supply networks. The device enables the simulation of 1- or 3-phase networks with a nominal voltage of 230 V and offers a variety of adjustable parameters to replicate realistic measurement conditions. It is especially suitable for training electricians, installers, maintenance technicians, and electrical engineers in industrial environments.
Applications
This device is primarily used in educational settings to practice the operation of measuring instruments and the analysis of power and fault parameters in electrical networks. It simulates realistic conditions without exposing participants to dangerous voltages. The simulation includes the representation of voltage, current, active power, reactive power, phase shift, harmonic content, and other electrical quantities that can be measured with appropriate instruments. It is applied in training courses, educational institutions, and continuing education centers where a safe and controlled environment for practical exercises is required.
Functions and Equipment in Detail
The device allows individual switching of each phase, enabling the simulation of both single- and three-phase networks. Current strength can be set in five fixed values (1, 2, 5, 10, 20 A), with a tolerance of ±10 % specified. The output voltage is variable and set to mains voltage ±15 %, allowing flexible adaptation to different measurement conditions. Phase shift between current and voltage can be adjusted in three fixed values (30°, 45°, 60° ±5°), with both inductive and capacitive shifts possible. Harmonic content can be set in three levels (mains component, 15 %, 25 %) or variably, to demonstrate the effects of harmonics on measurements.
Explaining Technology in an Understandable Way
The simulation is performed via a modular system connected to the 230 V mains network using a grounding plug. The device features an input filter and slow-acting fuses to enhance reliability and safety. A warning light indicates when voltage is present at the outputs, increasing safety during handling. The output power is defined by the set current and voltage values, with maximum values limited by the fuses. The simulation of harmonics allows investigation of the effects of non-sinusoidal currents on measuring instruments and network components.
Compatibility and Accessories
The device is designed for use with suitable measuring instruments capable of capturing electrical quantities such as voltage (U), current (I), active power (W), reactive power (var), phase shift (ϕ), harmonic content (THD), and energy (W/h). It is not specifically intended for particular devices but serves as a universal simulation device. Compatibility depends on the connection options and measurement ranges of the instruments used.
Mounting and Installation
Installation is performed by connecting the device to a 230 V mains socket using the grounding plug. No additional mounting work or tools are required. The device is immediately ready for use once connected. Operation is performed via switches and adjustment options on the front panel of the device. The warning light indicates the presence of voltage, which should be considered during commissioning and maintenance.
Advantages in Operation
The device provides a safe and controlled environment for practical training. The ability to individually vary parameters such as voltage, current, phase shift, and harmonics enables detailed analysis of their effects on measurement results. Individual phase switching allows simulation of faults such as phase failure or unbalanced loads. Compliance with the IEC 61010 300 V CAT II standard ensures safety during handling and suitability for use in environments with moderate electrical hazard. The robust packaging in a portable case facilitates transportation and use at various locations.
Protection Rating and Safety
The device complies with the safety standard IEC 61010 for electrical measuring instruments and systems in category 300 V CAT II. This means it is suitable for use in electrical installations with voltages up to 300 V and in environments with moderate hazard (e.g., in buildings, during installations). The warning light for applied voltage and the slow-acting fuse increase safety during operation. The device is not intended for outdoor use or in explosive environments.
Application Scenarios
The device is used in training courses, training centers, and continuing education institutions to practice the operation of measuring instruments and the analysis of electrical networks. It is particularly useful for teaching knowledge about power analysis, fault diagnosis, and the effects of harmonics. The simulation of various load conditions and fault scenarios enables a deep understanding of electrical processes in networks.