| General |
| Degree of protection | UV-resistant |
| Temperature range in motion | -5 °C |
| Temperature range for fixed installation | -40 °C |
| Nominal voltage | 0,6/1 kV |
| Insulation resistance | 20 MΩ·km |
| Current carrying capacity | according to DIN VDE part 4 |
| Minimum bending radius | 20 x conductor Ø |
| Radiation resistance | 80x10^6 cJ/kg |
| Coupling resistance | 250 Ω/km |
| Shield braid | tinned Cu wires, 85 % coverage |
| Wire insulation | Special PVC, T12 |
| Outer sheath | Special PVC, type TM2, black |
| Chemical resistance | highly oil resistant |
| Flame retardancy | Self-extinguishing, test type B |
| EMC | high shielding density |
| Protective conductor | green-yellow, in outer layer |
| Copper stranded wire | blank, fine-stranded, Class 5 |
| Installation | fixed installation, not in earth or water |
The YSLYCY-JZ 4x1.5 0.6/1kV BLACK is a flexible PVC control cable from manufacturer böhm Kabel, designed for use in industrial applications such as machine tools, conveyor and transfer belts, production lines, plant engineering, and climate technology, as well as in steelworks and rolling mills. The cable is designed for moderate mechanical stress and is suitable for flexible installation with free movement without tensile load and without forced guidance. It can be permanently installed in dry, damp, and wet rooms as well as outdoors, but not directly in soil or water. The black special PVC outer sheath is UV-resistant, making the cable particularly suitable for use in regions with high solar radiation, such as southern Europe, the Arab world, Asia, and the eastern region. The conductors are marked with a continuous white digit print, enabling clear identification of individual conductors even when stripped short. Base lines prevent misreading of digits. The green-yellow protective conductor is arranged in the outer layer, ensuring safe visibility.
Applications
The cable is primarily used in industrial automation, where it serves measurement, control, and control purposes. It is suitable for installations with moving parts requiring a flexible yet stable connection. The UV resistance and extended rated voltage range make it particularly suitable for use in regions with high ambient temperatures and intense solar radiation. The cable is not intended for direct underground or underwater installation, but for permanently installed applications in indoor and outdoor environments.
Functions and Equipment in Detail
The cable features a bare, fine-stranded Cu conductor according to DIN VDE Class 5 or IEC Class 5, ensuring high flexibility and durability. The conductors are insulated with special PVC insulation T12 according to DIN VDE Part 1, providing good electrical insulation and mechanical stability. The black conductors are marked with a continuous white digit print according to DIN VDE for clear identification. The green-yellow protective conductor is arranged in the outer layer from three conductors onwards. The conductors are stranded in layers with optimal lay lengths to ensure even distribution of mechanical stress. A shielding braid made of tinned copper wires with approximately 85% coverage ensures high shielding density and thus interference-free signal transmission. The special PVC outer sheath is black, type TM2 according to DIN VDE Part 1, and exhibits high oil resistance and chemical resistance. The material is self-extinguishing and flame-retardant, test type B according to VDE Part 804 and IEC-1, enhancing operational safety.
Technology Explained Simply
The high shielding density of the copper braid minimizes electromagnetic interference (EMC), which is particularly important when the cable is used in environments with strong electromagnetic fields, such as near motors or transformers. The recommendation for bilateral and extensive grounding of the shielding braid serves to optimize EMC properties. The UV resistance of the outer sheath prevents premature aging due to sunlight exposure, extending the cable's service life. The self-extinguishing and flame-retardant properties of the PVC sheath reduce fire risk in the event of a short circuit or overload. The radiation resistance up to 80 Mrad also makes the cable suitable for applications where it may be exposed to ionizing radiation.
Compatibility and Accessories
The cable is designed for use in industrial control and transmission systems and can be connected to standard terminals, connectors, and other electrical components suitable for PVC control cables. The use of appropriate protective and shielding connections is recommended to maintain EMC properties.
Installation and Mounting
The cable is designed for flexible installation and must not be installed under tensile stress. The minimum bending radius is 20 times the cable diameter, which must be considered during installation to avoid damaging the conductors. Installation is permanent, without forced guidance, in dry, damp, and wet rooms as well as outdoors. The cable must not be laid directly in soil or water. Installation is typically carried out by qualified electricians who comply with DIN VDE and IEC regulations.
Operational Advantages
The cable offers high mechanical and chemical resistance, enabling long service life and low maintenance frequency. UV resistance and flame-retardant properties enhance operational safety. Interference-free signal transmission via the shielding braid ensures reliable performance in electrical control and transmission systems. Clear conductor identification simplifies installation and maintenance. The cable is suitable for a wide range of industrial applications and meets requirements for safety, reliability, and functionality.
Operating Temperature Range
The cable can be operated in moving applications within a temperature range of -5 °C to +70 °C. The insulation resistance is at least 20 MΩ·km. Current loading capacity is to be determined according to DIN VDE Part 4. The coupling resistance of the shielding braid is maximum 250 Ω/km.