Böhm Kabel YSLYCY-JZBLACK3x1,0-

böhm Kabel YSLYCY-JZBLACK3x1,0- control cable 3x1,0 mm² black

Cables > Control line > Flexible Control lines

böhm Kabel YSLYCY-JZBLACK3x1,0- control cable 3x1,0 mm² black

Lieske Part No. 500264
Mfg Part No YSLYCY-JZBLACK3x1,0-
EAN-Code
Manufacturer Böhm Kabel
Here only 3,43 EUR
4,08 EUR incl. VAT

Further information for böhm Kabel YSLYCY-JZBLACK3x1,0- control cable 3x1,0 mm² black

General
Degree of protectionUV-resistant
Temperature range in motion-5 °C
Temperature range for fixed installation-40 °C
Nominal voltage0,6/1 kV
Insulation resistance20 MΩ·km
Coupling resistance250 Ω/km
Minimum bending radius20 x conductor Ø
Shield braidTinned Cu wires
Shielding coverca. 85 %
Wire insulationspecial PVC T12
Outer sheathSpecial PVC type TM2
Chemical resistancehighly oil resistant
Flame retardancySelf-extinguishing, test type B
Radiation resistance80 Mrad
Core numberingSequential white digit print
Protective conductorYellow-green, in outer position
Copper stranded wireblank, fine-stranded, Class 5
Current carrying capacityaccording to DIN VDE part 4
The YSLYCY-JZ 3x1.0 0.6/1kV BLACK is a flexible PVC control cable from manufacturer böhm Kabel, designed for use in industrial applications such as machine tools, conveyor and transfer belts, production lines, plant engineering, as well as in climate technology and in steelworks and rolling mills. The cable is designed for medium mechanical stress and is suitable for flexible installation with free movement without tensile stress and without forced movement guidance. It can be permanently installed in dry, damp, and wet rooms as well as outdoors, but not directly in earth or water. The black special PVC outer sheath is UV-resistant, making the cable particularly suitable for use in regions with high solar radiation, such as in southern Europe, the Arab world, Asia, and the eastern region.

Applications

The cable is primarily used in industrial automation, where it serves for measurement, control, and signaling purposes. Its construction allows for flexible installation in production environments with variable movement, for example in production lines or on movable machine parts. The UV resistance and extended rated voltage range also make it suitable for outdoor installations where it is exposed to weather conditions over a long period. The cable is installed permanently, but is not intended for direct embedding in earth or water.

Functions and Equipment in Detail

The cable features a bare, fine-stranded Cu conductor according to DIN VDE Class 5 or IEC Class 5, ensuring high flexibility and durability. The conductors are insulated with special PVC insulation T12 according to DIN VDE Part 1. The black conductors are marked with a continuous white digit print according to DIN VDE, allowing for clear identification of the conductors even with short stripping. Base lines prevent misreading of the digits. The green-yellow protective conductor is arranged in the outer layer, enhancing electrical safety. The conductors are stranded in layers with optimal lay lengths to ensure even distribution of mechanical stress.

Technology Explained Simply

A key component of the cable is the shielding braid made of tinned copper wires with a coverage of approximately 85%. This braid provides high shielding density and ensures interference-free transmission of signals and impulses. Electromagnetic compatibility (EMC) is supported by this shielding. To further optimize EMC properties, it is recommended to provide a double-sided and large-area all-around contact of the copper braid. The special PVC outer sheath type TM2 according to DIN VDE Part 1 is largely oil-resistant, self-extinguishing, and flame-retardant according to test method B as per VDE Part 804 and IEC-1. The radiation resistance is up to 80 Mrad, making the cable suitable for applications with increased radiation exposure.

Compatibility and Accessories

The cable is designed for use in industrial control and transmission systems where high EMC and mechanical robustness are required. It can be connected with standard cable lugs, connectors, and other connection elements suitable for PVC control cables. The use of appropriate shielded cable lugs or connectors for secure contact of the shielding braid is recommended to maintain EMC properties.

Installation and Mounting

The cable is designed for flexible installation with free movement. The minimum bending radius is 20 times the cable outer diameter. During installation, care must be taken to ensure the cable is not laid directly in earth or water. The cable is installed permanently, with medium mechanical stress. The conductors are connected using suitable connection elements, and the shielding should be contacted double-sided and over a large area as recommended.

Advantages in Operation

The high shielding density of the copper braid ensures interference-free signal transmission, which is particularly advantageous in electromagnetically noisy environments. The UV resistance of the outer sheath extends the cable's service life in outdoor installations. The oil-resistant and self-extinguishing PVC insulation increases safety and resistance to chemical influences. The continuous digit numbering of the conductors simplifies identification and installation, especially in complex systems. Current loading is according to DIN VDE Part 4, with the exact loading depending on the specific installation conditions.

Temperature Range and Electrical Properties

The cable can be operated in the temperature range of -5 °C to +70 °C when installed with movement. For permanently installed arrangements, the temperature range is -40 °C to +80 °C. The rated voltage is U(0)/U 0.6/1 kV. The insulation resistance is at least 20 MΩ·km. The coupling resistance of the shielding braid is maximum 250 Ω/km. Current loading is according to DIN VDE Part 4, with the exact loading depending on the specific application and environment.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/500264
qrcode für böhm Kabel YSLYCY-JZBLACK3x1,0- control cable 3x1,0 mm² black