General
Nominal voltage300/500 V
Maximum permissible operating voltage for AC and three-phase systems330/550 V
Maximum permissible operating voltage for DC systems825 V
Short-circuit temperature250 °C
Conductor resistanceaccording to DIN/VDE
Test voltage50 Hz, 5 min.
Insulation materialhalogen-free cross-linked polymer blend
Circuit board constructionFine-stranded bare
ColourViolet
Application areaDry rooms, wiring of luminaires, devices, control panels, distributors, buildings with high personnel and asset concentration, vehicles
Installation methodin conduits, on, in and under plaster, in closed installation channels
Featuresflame retardant, halogen-free, minimal smoke density
StandardsDIN VDE Part 3
The H07Z-K 1.5 VIO is a halogen-free single-core cable from the manufacturer böhm Kabel, specifically designed for use in dry rooms. It is used for wiring of lighting fixtures, devices, control panels, and distributors, particularly in buildings with high personnel or asset concentration, as well as in vehicles. The cable is suitable for installation in conduits, on, in, and under plaster, as well as in closed installation channels. It may also be used for internal wiring of devices, control panels, and distributors, as well as for protected installation in and on lighting fixtures. General requirements are based on DIN VDE Part 3. The maximum operating temperature at the conductor is 90 °C.

Applications
This cable is intended for use in indoor environments, particularly in areas with increased safety requirements such as office buildings, hospitals, schools, or public transport vehicles. It is suitable for electrical wiring of lighting systems, electrical devices, and control panels. Installation is carried out in closed installation systems such as conduits or channels, and the cable may also be installed under plaster or within wall linings. The application is exclusively in dry rooms.

Functions and Features in Detail
The H07Z-K 1.5 VIO features a fine-stranded, bare conductor, providing high flexibility and easy handling. The insulation consists of a halogen-free, cross-linked polymer blend, protecting the cable against fire and heat. The cable is flame-retardant and exhibits minimal smoke density, ensuring better visibility and reduced toxicity of smoke gases in case of fire. These properties make it particularly suitable for rooms with high visitor traffic or for use in vehicles.

Technical Explanation
The designation H07Z-K refers to a halogen-free single-core cable with a rated voltage of 300/500 V or 450/750 V. The maximum operating voltage in alternating current and three-phase systems is 330/550 V or 495/825 V, respectively, and 825 V in direct current systems. The cable is designed for an operating temperature of up to 90 °C at the conductor, and can withstand short-term temperatures up to 250 °C during a short circuit. The conductor resistance complies with DIN/VDE standards. The insulation is based on a cross-linked polymer blend, enhancing mechanical stability and thermal resistance.

Compatibility and Accessories
The cable is designed for use in standard installation systems and can be installed using common installation techniques. It is compatible with conduits, installation channels, and other closed installation methods. Its use in conjunction with other halogen-free cables or in systems requiring high safety standards is possible.

Installation and Mounting
Installation is carried out in dry rooms and requires routing in closed installation systems such as conduits or channels. The cable can be installed on, in, and under plaster. Processing is done using standard tools for electrical installations. The cable is flexible and easily bent, facilitating installation in confined spaces. Connections are made using suitable connectors or terminals appropriate for the rated voltage and cross-section.

Operational Advantages
The H07Z-K 1.5 VIO provides high safety during operation due to its flame-retardant and halogen-free properties. The minimal smoke density improves visibility in case of fire and reduces the risk of toxic gases. The high thermal resistance allows safe use at conductor temperatures up to 90 °C. The cable is suitable for use in buildings with high personnel and asset concentration, making it a reliable choice for critical applications. The flexibility of the fine-stranded conductor facilitates installation and handling in complex installation systems.

Protection Class
The cable is not classified by protection class, as it does not have an external protective housing or specific IP rating. Protection is provided by the insulation materials and the use in closed installation systems.

Color and Identification
The cable is manufactured in violet color, distinguishing it visually from other cables. The color serves as identification and facilitates recognition within the installation network. Identification is done via the designation H07Z-K 1.5 VIO, which is indicated on the cable itself or on the packaging material.

Standards and Norms
The cable is designed for use in dry rooms and in closed installation systems.

Application Safety
The cable is intended for use in dry rooms and must not be installed in damp or wet areas. Use in open installation systems is not recommended, as the cable is designed for closed installation methods. The maximum operating temperature at the conductor is 90 °C, with the cable capable of withstanding short-term temperatures up to 250 °C.

Materials and Environment
The insulation consists of a halogen-free, cross-linked polymer blend, which is more environmentally friendly than halogen-containing materials. The use of halogen-free materials reduces the formation of toxic gases in case of fire and improves safety during operation. The cable is suitable for use in buildings with high personnel and asset concentration, emphasizing its environmental and safety relevance.

Processing Properties
The cable is flexible and easily bent, facilitating processing in confined spaces. The fine-stranded conductor enables easy handling and good connection with connectors or terminals. Installation is carried out in closed installation systems, where the cable can be routed in conduits, channels, or under plaster.

Safety Features
The cable is flame-retardant and exhibits minimal smoke density. These properties enhance safety in case of fire and reduce the risk of toxic gases. The cable is suitable for use in buildings with high personnel and asset concentration, emphasizing its safety relevance.

Compatibility
The cable is designed for use in standard installation systems and can be installed using common installation techniques. It is compatible with conduits, installation channels, and other closed installation methods. Its use in conjunction with other halogen-free cables or in systems requiring high safety standards is possible.

Safety Aspects
The cable is flame-retardant and exhibits minimal smoke density. These properties enhance safety in case of fire and reduce the risk of toxic gases. The cable is suitable for use in buildings with high personnel and asset concentration, emphasizing its safety relevance.

Environmental Aspects
The insulation consists of a halogen-free, cross-linked polymer blend, which is more environmentally friendly than halogen-containing materials. The use of halogen-free materials reduces the formation of toxic gases in case of fire and improves safety during operation. The cable is suitable for use in buildings with high personnel and asset concentration, emphasizing its environmental and safety relevance.

Processing Properties
The cable is flexible and easily bent, facilitating processing in confined spaces. The fine-stranded conductor enables easy handling and good connection with connectors or terminals. Installation is carried out in closed installation systems, where the cable can be routed in conduits, channels, or under plaster.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/498906
qrcode für böhm Kabel XXXXX H07Z-K 1,5 VIO cable violet