| General |
| Nominal voltage | 300/300 V |
| Test voltage | 2000 V |
| Installation temperature range | +5 °C - +70 °C |
| Temperature range after installation | -30 °C - +70 °C |
| Operation temperature | +70 °C |
| Bending radius | 7.5 x cable diameter min. |
| Flame retardancy | VDE 0472 T. 804 test type B (IEC 332-1) |
| Conductor marking | according to VDE 0293-308 |
| Conductor | Copper stranded wire, bare, fine-stranded |
| Wire insulation | PVC according to VDE 0207 |
| Sheath colour | Grey |
| Protective conductor | with earth conductor gn-ye |
The cable H03VV-F 3G0.75 GR from böhm Kabel is a lightweight PVC-sheathed cable designed for connecting electrical appliances with low mechanical stress. It is suitable for applications such as radio equipment, lighting, vacuum cleaners, or kitchen appliances, but not for heating and cooking appliances, nor for outdoor use. The designation 3G0.75 refers to three conductors each with a cross-section of 0.75 mm², where G indicates the integrated protective conductor (gn-ge). The sheath colour is grey, enabling clear identification during installation.
Applications
This cable is designed for indoor use where there are no strong mechanical loads or high temperatures. It is not suitable for outdoor use, as it does not offer protection against weather influences such as rain or moisture. Its application is limited to household appliances and small electrical devices that do not generate high current loads or thermal stress.
Functions and Equipment in Detail
The cable consists of bare, fine-stranded copper wires, ensuring high flexibility and good electrical conductivity. The conductor insulation is made of PVC according to VDE 0207, providing sufficient insulation and mechanical stability. Conductor identification follows VDE 0293-308, enabling unambiguous assignment of conductors during installation and mounting. The sheath is grey; additional colours are available upon request.
Technology Explained Simply
The rated voltage is 300/300 V, meaning the cable is designed for alternating voltages up to 300 V and direct voltages up to 300 V. The test voltage of 2000 V serves safety testing and ensures the insulation remains stable even under increased voltage. The maximum operating temperature is +70 °C, with the cable allowed to be installed between +5 °C and +70 °C, and used after installation between -30 °C and +70 °C. The minimum bending radius is 7.5 times the cable diameter, enabling flexible installation without damage. Flame retardancy corresponds to VDE 0472 Part 804, Test Method B (equivalent to IEC 332-1), ensuring limited flame spread in case of fire.
Compatibility and Accessories
The cable is suitable for use with standard sockets and switches rated for 300/300 V. It can be combined with other cables of type H03VV-F, provided the cross-sections and electrical requirements match.
Installation and Mounting
Installation is carried out by laying indoors, with temperature requirements strictly observed. The cable must not be laid outdoors, as it lacks protection against weather influences. Its flexibility allows for flexible routing, but the minimum bending radius of 7.5 times the diameter must be maintained to ensure cable integrity.
Operational Advantages
The cable offers high flexibility due to fine-stranded copper wires, enabling easy installation and mounting. PVC insulation ensures sufficient electrical insulation and mechanical stability. Flame retardancy according to VDE 0472 Part 804, Test Method B, increases safety in case of fire. Clear conductor identification according to VDE 0293-308 simplifies installation and maintenance.
Protection Rating
The cable is not suitable for outdoor use, as it does not have a specific protection rating against weather influences. Indoor use is, however, feasible as long as temperature and mechanical requirements are met.
Operating Voltage
The rated voltage of 300/300 V is suitable for household and small-scale applications, with the cable not designed for higher voltages.
Flame Retardancy
Flame retardancy according to VDE 0472 Part 804, Test Method B (IEC 332-1), ensures the cable spreads flame only limitedly in case of fire, enhancing safety.
Conductor Identification
Conductor identification follows VDE 0293-308, enabling unambiguous identification of conductors and preventing errors during installation.
Copper Wire
The use of bare, fine-stranded copper wires ensures high flexibility and good electrical conductivity, which is advantageous for applications requiring movement or flexible routing.