| General |
| Cable type | H03VV-F |
| Number of cores | 2 |
| Core cross section | 0,5 mm² |
| Sheath colour | White |
| Protective conductor | None |
| Nominal voltage | 300/300 V |
| Test voltage | 2000 V |
| Operation temperature | +70 °C |
| Installation temperature range | +5 to +70 °C |
| Temperature range after installation | -30 to +70 °C |
| Bending radius | 7,5 x cable diameter |
| Flame retardancy | VDE 0472 Part 804, test type B |
| Wire insulation | PVC according to VDE 0207 |
| Conductor marking | according to VDE 0293-308 |
| Conductor material | Copper stranded wire, bare, fine-stranded |
The cable H03VV-F 2X0.5 WS from böhm Kabel is a lightweight PVC-sheathed cable designed for connecting electrical appliances with low mechanical stress. It is suitable for applications such as radio equipment, lighting, vacuum cleaners, or kitchen appliances, but not for heating or cooking appliances, nor for outdoor use. The designation H03VV-F refers to the cable's standardization, where H03 indicates the category for lightweight sheathed cables, VV denotes the use of PVC for both conductor and sheath insulation, and F indicates fine-stranded copper conductors. The specification 2X0.5 WS means the cable has two conductors, each with a cross-section of 0.5 mm², where WS stands for white protective conductor cable — in this case, without a protective conductor (X = without protective conductor). The sheath color is white, enabling clear visual identification, especially in indoor environments.
Applications
This cable is designed for indoor use where there are no high mechanical loads or extreme environmental conditions. It is not suitable for outdoor use, as it lacks protection against weather influences such as rain or moisture. Its application is limited to lightly loaded devices that do not require high current or thermal loads. Use with heating or cooking appliances is excluded, as these generate higher thermal stress that could overload the cable.
Functions and Equipment in Detail
The cable consists of fine-stranded, bare copper conductors, providing high flexibility and easy handling. The conductor insulation is made of PVC, specified according to VDE 0207, ensuring high electrical insulation capability and chemical resistance. Conductor identification follows VDE 0293-308, enabling clear identification during installation and mounting. The sheath color is white, supporting clear visual differentiation from other cables in the installation. The cable is manufactured without a protective conductor (X), which is sufficient for applications with low risk of electric shock.
Technology Explained Simply
The rated voltage is 300/300 V, meaning the cable is designed for an operating voltage of up to 300 V between conductor and earth, and between conductors. The test voltage of 2000 V ensures quality control and verifies that the insulation remains intact under increased electrical stress. The maximum operating temperature is +70 °C, defining the thermal load capacity of the cable. The temperature range for installation is between +5 °C and +70 °C, and after installation between -30 °C and +70 °C, allowing use in indoor environments with varying climate conditions. The minimum bending radius is 7.5 times the cable diameter, enabling flexible installation without damaging the conductors. Flame retardancy complies with VDE 0472 Part 804, Test Method B (equivalent to IEC 332-1), meaning the cable does not produce flaming droplets during a fire test, thus presenting a low fire hazard.
Compatibility and Accessories
The cable is suitable for use in electrical installations with low mechanical stress. It can be connected to standard sockets, switches, and appliance connection outlets designed for a rated voltage of 300/300 V. The use of a protective conductor is not intended, as the cable is manufactured without a protective conductor (X). For applications requiring a protective conductor, other types such as H03VV-F with protective conductor (G) or H05VV-F are recommended. The cable is not suitable for outdoor use or in damp environments, as it does not have special protection against weather influences.
Installation and Mounting
Installation involves laying the cable indoors, ensuring the installation temperature range (+5 °C to +70 °C) is observed. The cable can be bent and cut, with the minimum bending radius of 7.5 times the diameter maintained to avoid damaging the conductors. Conductor identification according to VDE 0293-308 facilitates correct assignment when connecting to sockets or appliances. The use of appropriate tools such as cutters, cable strippers, and insulating tape is recommended to ensure a clean and safe connection.
Operational Advantages
The cable offers high flexibility due to its fine-stranded copper construction, facilitating installation in confined spaces or complex routing. The PVC insulation ensures reliable electrical insulation and chemical resistance. Flame retardancy according to VDE 0472 Part 804, Test Method B, reduces fire hazard in case of a short circuit. Clear conductor identification and the white sheath color simplify identification and maintenance within the installation network. The cable is suitable for use in domestic and commercial indoor environments where no high mechanical or thermal loads occur.