| General |
| Nominal voltage | 0,6/1 kV |
| Test voltage | 2500 V |
| Temperature range for fixed installation | -20 to +80 °C |
| Temperature range in motion | -40 to +80 °C |
| Maximum operating temperature | +90 °C |
| Maximum permissible static tensile load | 20 N/mm² |
| Minimum bending radius for drum operation < 21.5 mm | 5 x outer diameter |
| Minimum bending radius drum operation > 21.5 mm | 6.25 x outer diameter |
| Minimum bending radius for roller deflection | 7.5 x outer diameter |
| Flame retardancy | VDE 0482-332-1-2, IEC 60332-1 |
| Conductor | tinned copper stranded wire, fine-stranded, class 5 |
| Wire insulation | Rubber compound according to VDE 0207 T. 20 |
| Conductor marking | made of rubber compound |
| Torsion protection insert | made of high-tensile plastic according to VDE 0293-308 |
| Outer sheath | rubber compound |
| Sheath colour | Black |
| Drum speed | up to 120 m/min |
The rubber hose cable NSHTÖU-J 12 X 2.5 from böhm Kabel is a special cable specifically developed for dynamic operating conditions. It is particularly used in installations with frequent winding and unwinding, such as lifting equipment, transport and conveying systems, where the cable is simultaneously subjected to tensile stress and forced guidance. The cable is designed for high mechanical loads and is suitable for use in damp and wet rooms, outdoors, in explosion-hazard areas, and in underground mining. The drum speed reaches up to 120 m/min, making it suitable for demanding industrial applications.
Applications
The cable is designed for moving installations where the cable is regularly wound and unwound. It is particularly suitable for installations with high mechanical loads, such as conveyor belts, cranes, or mobile work equipment. The operating conditions also include damp and wet environments as well as outdoor use, and the cable can be used in explosion-hazard areas and in underground mining. The maximum drum speed of 120 m/min enables use in fast, automated production environments.
Functions and Equipment in Detail
The cable consists of copper strands that are tinned, fine-stranded, and conform to class 5 according to VDE 0293-308. The conductors are insulated with a rubber compound meeting the requirements of VDE 0207 T. 20. The conductors are stranded with short lay length, ensuring high flexibility and resistance to torsion. A neutral conductor is not present. Conductor identification is also made from rubber compound, supplemented by a torsion protection insert made of high-tensile plastic, which increases mechanical stability. The inner and outer sheaths are also made of rubber compound, with the outer sheath being black in colour.
Technology Explained Simply
The rated voltage is 0.6/1 kV, making the cable suitable for use in industrial power supplies with voltages up to 1000 V. The test voltage of 2500 V ensures electrical insulation under high voltage loads. The operating temperature can reach up to +90 °C, with the operating temperature range varying depending on installation: for fixed surface installation, the range is -20 °C to +80 °C; for moving installation, it is -40 °C to +80 °C. The maximum permissible static tensile stress on the conductor is 20 N/mm². The minimum bending radius depends on the outer diameter: for cables with an outer diameter below 21.5 mm, it is 5 times the outer diameter; for cables above 21.5 mm, it is 6.25 times the outer diameter. For drum deflection, the minimum bending radius is 7.5 times the outer diameter. Flame retardancy complies with standards VDE 0482-332-1-2 and IEC 60332-1, making the cable suitable for use in hazardous areas.
Compatibility and Accessories
The cable is designed for use in industrial installations subject to high mechanical and thermal loads. The use of protective and/or neutral conductors is only permitted if they have the same cross-section as the phase conductors and are not split. Dynamic tensile stress must be determined individually depending on the application.
Installation and Mounting
Installation must consider the specified minimum bending radii to ensure the cable’s service life. In drum operation, the bending radius depends on the cable’s outer diameter. The cable is designed for flexible installation, with tensile stress and bending loads during operation needing to be considered. Installation is surface-mounted, with temperature conditions varying depending on the installation method.
Operational Advantages
The cable is characterised by high mechanical strength, flexibility, and resistance to tensile and torsional loads. The rubber compound of the outer sheath provides protection against moisture, mechanical damage, and chemical influences. The flame-retardant design increases safety in hazardous areas. The high drum speed of 120 m/min enables use in fast, automated systems. The cable is suitable for use in explosion-hazard areas and in underground mining, increasing its versatility. The combination of high tensile strength, flexibility, and chemical resistance makes it a reliable solution for demanding industrial applications.