| General |
| Degree of protection | not specified |
| Operating temperature moving | -5 °C |
| Operating temperature non-moving | -40 °C |
| Bending radius when moved | 10 x cable diameter |
| Bend radius for fixed installation | 7,5 x cable diameter |
| Nominal voltage | 300/500 V |
| Test voltage | 2000 V |
| Flame retardancy | VDE 0472 T. 804 test type B |
| Conductor marking | VDE 0293-308 |
| Conductor | bare copper stranded wire, fine-stranded |
| Conductor class | VDE 0295 Class 6 |
| Wire insulation | PVC |
| Sheath | PVC compound |
| Sheath colour | Grey |
| Core identification JZ | black conductors with continuous digit marking and green-yellow protective conductor |
The YSLY-HF-JZ 3x2.5 from böhm Kabel is a highly flexible PVC drag chain cable, specifically designed for use in moving installations. It serves as control, measurement, and regulation cabling in machine tool engineering, plant and apparatus construction, as well as in transport and conveyor technology. It is particularly suitable for use in cable drag chains, on assembly belts, and in robotics, where it must withstand constant bending stress and continuously moving current collectors. The cable is intended for installation in dry and damp indoor environments, but not for outdoor use.
Applications
This cable is designed for applications requiring high mobility and flexibility. It is frequently used in machines with moving parts, such as CNC systems, conveyor systems, or automated assembly lines. Its construction allows for long-term use under continuous bending stress, making it ideal for use in drag chains, where cables are regularly pulled back and forth.
Functions and Features in Detail
The cable consists of bare copper strands, finely stranded according to VDE 0295 Class 6. This construction ensures high flexibility and durability under dynamic conditions. The conductors are insulated with PVC and marked according to VDE 0293-308. The designation JZ indicates that the conductors are black and marked with a continuous numerical print, including a green-yellow protective conductor. The stranding is done in extremely short lay lengths in layers, supplemented by a nonwoven tape, which increases the mechanical stability and flexibility of the cable. The sheath is made of a PVC compound and is gray in color.
Technology Explained Simply
The high flexibility of the cable is achieved through the fine-stranded copper wire, which can deform without cracking under frequent bending. The small bending radius of 10 times the cable diameter for moving installations and 7.5 times for fixed installations enables compact installation, even in tight curves. The temperature resistance is -5 °C to +70 °C for moving installations and -40 °C to +70 °C for fixed installations. The flame retardancy corresponds to test method B according to VDE 0472 Part 804 (equivalent to IEC 332-1), indicating limited flammability under defined conditions.
Compatibility and Accessories
The cable is designed for use in moving systems and can be combined with other components of the same type to create complete cable systems for drag chains. The rated voltage is 300/500 V and 500/750 V, with test voltages of 2000 V and 3000 V. These values are relevant for safe electrical use in industrial installations. The cable is not intended for outdoor use, as it is not designed for weather exposure.
Installation and Mounting
Installation takes place in moving installations, where the cable is routed in drag chains or on assembly belts. The bending radii are designed to allow routing in tight curves without compromising the mechanical integrity of the cable. Installation is carried out indoors, with ambient temperatures within the specified limits. The cable is not intended for use in explosive environments.
Operational Advantages
The high flexibility and small bending radius enable efficient and compact installation in moving systems. The cable withstands continuous bending stress, extending its service life in dynamic applications. The flame retardancy according to VDE 0472 Part 804, test method B, ensures increased safety during operation. The clear conductor marking according to VDE 0293-308 simplifies installation and maintenance.