Further information for Balluff BNS 813-D03-R12-100-10-01-FD (BNS00W0)
For safety functions such as emergency stop or end position limitation with safety switches according to DIN EN 60204-1/VDE 0113The switching process is triggered by a rigid plunger that actuates a mechanical switching element with positive opening. Switching is ensured even with welded contacts.The number of safety switching points is arbitrary and can be combined with standard switching elements. Dimensions=120 x 80 x 85 mm, housing material=aluminum, number of switching points=3x roller, design=safety DIN EN 60204-1, operating principle=1-3. Switching point: mechanical, continuous current=1-3. Switching point: 6 A, rated operating voltage Ue=1-3. Switching point: 250 V AC, installation=vertical, approach direction=longitudinal, parallel to the screwing surface, approach speed=1-3. Switching point: 60 m/min, switching point spacing=12 mm, connection type=1-3. Switching point: screw connection, ambient temperature=-5...85 °C, protection class=IP67, approval/conformity=CECCCWEEE