General
Degree of protectionIP55
Just-operate current< 30 mA
Trip time< 30 mS
Nominal current16 A
Operating voltage250 V
Frequency50 Hz
The PRCD INLINE residual current device from Bachmann, type 919.189, is a safety device for use in electrical installations, ensuring protection of persons against dangerous touch currents. It is black in colour and designed for use in indoor environments as well as in slightly damp conditions, with protection class IP55 providing protection against dust and splashing water. This makes it suitable for areas where increased humidity or mechanical stress may occur, for example in workshops, garages or outdoor areas with low exposure.

Applications
This residual current device is intended for use in electrical installations with an operating voltage of 250 V and a frequency of 50 Hz. It is rated for a maximum current of 16 A and is therefore suitable for protecting consumers operating within this power limit. Typical applications include safeguarding electrical appliances in residential and commercial buildings, particularly in areas where increased fire or electric shock hazards exist. The IP55 protection class also allows use in outdoor areas, provided there is no direct, continuous moisture or strong mechanical stress.

Functions and Equipment in Detail
The switch operates on the principle of a residual current device (PRCD), which automatically disconnects the circuit when a fault current exceeding a predefined threshold — here under 30 mA — is detected within a defined time — here under 30 milliseconds. This tripping current of under 30 mA is a standard value for personal protection, as it is below the threshold at which current flow through the human body becomes life-threatening. The tripping time of under 30 mS ensures a rapid response to minimise danger to the user. The mounting housing is designed as an inline module, meaning it can be installed into existing circuits without requiring a complete redesign.

Technology Explained Simply
The PRCD INLINE detects a fault current caused by insulation damage or contact with a conductive part. If the current flowing through the live conductor into the installation does not fully return via the neutral conductor, but instead partially flows through the ground or a person, this creates a fault current. The switch measures this difference and disconnects the circuit as soon as the fault current exceeds the predefined threshold of under 30 mA. The IP55 protection class means the device is protected against dust and splashing water, making it suitable for use in damp or dusty environments. The operating voltage of 250 V and frequency of 50 Hz correspond to standard values for alternating current networks in Germany.

Compatibility and Accessories
The residual current device is designed as an inline module and can be integrated into existing circuits. Suitable accessories available in the range include a protective earth conductor extension cable designated H07BQ-F3G1,5, orange, with a length of 3.0 metres. This extension is also equipped with PRCD protection and can be used together with the switch to enhance safety in power supply. The combination of switch and extension enables flexible and safe power supply in mobile or temporary installations.

Installation and Mounting
Mounting is carried out within the circuit, with the switch installed between the power source and the consumer. Installation requires interruption of the power supply and compliance with applicable electrical regulations. It is essential to ensure that electrical connections are correctly and securely wired to guarantee safe operation. The IP55 protection class does not require special measures during installation, although the switch should be protected from direct sunlight and strong mechanical stress.

Operational Advantages
Operation of the residual current device is simple and requires no special maintenance. The rapid response to fault currents ensures a high level of personal protection. The inline module mounting housing allows flexible integration into existing installations without requiring extensive redesign. The IP55 protection class extends the range of applications to damp or dusty environments, making the switch suitable for a wide variety of applications. The combination with suitable accessories such as the protective earth conductor extension enhances the flexibility and safety of the power supply.