| General |
| Degree of protection | Coarse and fine protection |
| Coarse protection technology | Gas tube conductor |
| Ignition voltage for coarse protection | 90 V |
| Arc voltage | < 20 V |
| Nominal discharge current for coarse protection | 2500 A |
| Pulse duration coarse protection | 8/20 µs |
| Fine protection technology | TRISIL diodes |
| Ignition voltage for fine protection | 75 V |
| Surge current for fine protection | 100 A |
| Surge duration for fine protection | 10 ms |
| Housing material | ABS |
| Colour housing | Grey |
The Auerswald surge protection module, manufacturer's number 90467, is a surge protection device for ISDN exchange lines in telephone systems. It provides protection against overvoltages caused by lightning strikes or electrical disturbances in the network. The device is installed between the telephone system and the postal TAE or NTBA socket to protect the system from damage due to high voltage impulses. The protection function is achieved through a combination of gas discharge tubes and TRISIL diodes, each responsible for coarse and fine protection respectively.
Applications
This surge protection module is specifically designed for use in ISDN telecommunication systems. It protects internal components of the telephone system, such as interface and signal processing electronics, from transient overvoltages. Installation is directly on the exchange line, thereby protecting the entire system from voltage spikes that could enter via the telephone line. It is intended for use in buildings with ISDN connections, particularly in areas with high susceptibility to lightning or electrical disturbances.
Functions and Features in Detail
The protection operates in two stages: coarse protection is provided by gas discharge tubes, which ignite at overvoltages of approximately 90 V and divert energy through a low arc voltage level (below 20 V). The nominal discharge current is 2500 A with an impulse duration of 8/20 µs, indicating the device’s capability to divert high energy amounts under transient conditions. Fine protection is ensured by TRISIL diodes, which activate at an ignition voltage of 75 V and can divert a surge current of 100 A over 10 ms. This combination ensures effective absorption of voltage spikes without affecting the signal quality of the ISDN connection.
Technology Explained Simply
The gas discharge tubes act as primary shielding against high voltage impulses by creating a conductive path when the ignition voltage (90 V) is exceeded, thereby diverting the energy. The arc voltage remains below 20 V to maintain the system voltage at a safe level. TRISIL diodes handle fine regulation and protect against residual voltages that may remain after coarse protection. The combination of both technologies ensures reliable protection, capturing both high-energy impulses and lower but critical voltage spikes.
Compatibility and Accessories
The device is designed for use on ISDN exchange lines and is connected between the telephone system and the TAE or NTBA socket. No specific accessories are required, as installation is directly onto the existing connection. Compatibility is limited to ISDN systems connected to the public telephone network via an exchange line.
Mounting and Installation
Installation is performed by direct connection between the telephone system and the postal TAE or NTBA socket. The device is housed in an ABS housing with a grey surface, designed to be robust and suitable for indoor use. Dimensions are 142 mm (width) × 81 mm (height) × 27 mm (depth). Installation requires no special tools or additional mounting effort; it is simply integrated into the existing line chain.
Operational Advantages
By combining coarse and fine protection, the device offers comprehensive protection for the telephone system. Its ability to divert high energy amounts (2500 A) protects against severe damage from lightning strikes. TRISIL diodes ensure precise protection against smaller, yet still dangerous, voltage spikes. Installation is simple and requires no modifications to the existing system. The device remains unobtrusive during operation and does not affect signal transmission, as the protection function is only activated during overvoltage events.