Aten PG8308G-AT, EAN: 4710469345739

Aten PG8308G-AT PDU 8-outlet 1U 32A

Aten PG8308G-AT PDU 8-outlet 1U 32A

Lieske Part No. 1558019
Mfg Part No PG8308G-AT
EAN-Code 4710469345739
Manufacturer Aten
Here only 640,02 EUR
761,62 EUR incl. VAT

Further information for Aten PG8308G-AT PDU 8-outlet 1U 32A

Certificates
CertificationCE, UKCA
Design
PDU typesMetered, Switched
Rack capacity1U
Product colourBlack
DisplayLCD
Features
Cable length3 m
Reset buttonYes
LED indicatorsYes
Logistics data
Country of originTaiwan
Management features
MonitoringCurrent, Voltage
Operational conditions
Operating temperature (T-T)0 - 60 °C
Storage temperature (T-T)-20 - 60 °C
Operating relative humidity (H-H)0 - 80%
Ports & interfaces
AC outlets quantity8 AC outlet(s)
Power plugIEC 60309
AC outlet typesC13 coupler, C19 coupler
Ethernet LAN (RJ-45) ports2
USB ports quantity1
Power
Nominal input voltage100 - 240 V
AC input frequency50-60 Hz
Maximum current32 A
Output voltage100 - 240 V
Load capacity7680 VA
Technical data
MountingVertical
U1
Output current16A
Number of C13 sockets6
TypePDU
Supply linePower cable with IEC 60309 32A plug
Number of C19 sockets2
Max. input power7680VA
Input C20No
Input C14No
Measuring functionYes
Input CE 16/32AYes
Switching functionYes
Protective functionYes
Weight & dimensions
Width210 mm
Depth432.4 mm
Height44 mm
Weight4.07 kg
The intelligent PG8308 series PDU from ATEN with power measurement and switching function has 8 sockets* in a compact 1U rack enclosure. With an ARM Cortex-A8 processor, these PDUs offer advanced control options via USB, COM, environmental sensors and two Gigabit LAN ports.
Designed for quick deployment, the PG series PDUs can power all connected devices within just 10 seconds of being plugged in. For improved cost efficiency and space optimisation, these intelligent PDUs can be cascaded, allowing up to 64 units to be connected together.
The PG series PDUs are equipped with RJ-45 sensor ports that can be connected to EA1640 to monitor the status of the data centre environment and ensure optimal operating conditions. They offer secure, centralised and intelligent power management functions that allow users to switch IT devices in the data centre, such as servers, storage systems, KVM switches, network devices and serial data devices, on and off or power cycle them.
By integrating remote power control and measurement, users can manage and monitor the power status of devices connected to PG Series PDUs from virtually anywhere via an IP connection. This functionality is available at the PDU device, bank or outlet level, depending on the model.
These intelligent PDUs are designed for high-voltage ranges from 100 V to 240 V. In addition, they provide accurate kWh energy consumption data with an accuracy of ±1%. This precision improves power consumption monitoring, helps determine baseline energy consumption and supports the tracking of energy efficiency initiatives.
In terms of hardware design, the PG series PDUs incorporate energy-saving relays – subtypes of electromagnetic switches – to manage large currents more efficiently, resulting in lower energy consumption compared to models without relays. The circuit breaker integrated into the PG series models supports current flows of 30 A or 32 A and automatically disconnects the power supply to prevent overloads and protect connected devices from damage.
The PG series firmware can be updated via the web GUI or USB, allowing users to conveniently download updates from the ATEN website. This ensures that they have access to the latest features and improvements for practical use.
A sticker for the green LCD console display is included, with additional options in blue, yellow, red and purple available for purchase. This colour-coding system improves the distinguishability between power settings and facilitates more efficient troubleshooting.
The PG Series intelligent PDUs are ideal for server rooms, network cabinets and enterprise data centres, providing an intelligent power distribution and management solution that meets the demands of high-density IT applications while optimising overall costs.
Note:
1. PG8308A has 8 x NEMA 5-20R outlet configurations
2. PG8308B / PG8308G has 6 x IEC60322 C13 and 2 x IEC60322 C19 outlet configurations
Connections
Supports 1 Gbit/s Ethernet interface
Remote management protocols – TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP (TLS 1.2), ARP, NTP, DNS, Auto Sense, Ping, SNMP V1, V2 and V3, Telnet, Modbus (via TCP/IP), WLAN and IPv6
Scripting – JSON-RPC protocol (Remote Procedure Call) and Python scripting for controlling specific PDU units
Security – 2-level account/password access and IP/MAC filter, 128-bit SSL
Authentication – RADIUS, LDAP, TACACS
Supports Eco DC and multiple browsers (IE, Firefox, Chrome and Safari)
Supports RS-232 and RS-485 communication ports
Automatic ping and reboot
The connection for environmental sensors enables an RJ-45 connection to connect or daisy chain up to 8 ATEN EA1640 environmental sensors for monitoring and controlling temperature, humidity, air flow, air pressure differences and leaks, with alerts for potential threats (sold separately)
Rotatable LCD screen – rotates 180 degrees for flexible rack installation
Measurement
Secure locking improvement prevents power cords from being pulled out due to vibration or human error
Measurement and monitoring of power at PDU and outlet level
Measurement and setting of thresholds for current, voltage, power, power loss, temperature and humidity
Accurate kWh measurement (+/-1%) for better power consumption habits, baseline values and initiative tracking
Real-time alerts on the LCD screen show you unusual power conditions:
Measurements on the start screen: A (total current), V (voltage), W (power), kWh (power consumption)
Types of alerts: Critical, Warning (value exceeds a preset threshold), Warning (value is approaching the warning threshold)
Network
Two Ethernet ports support cascading of up to 64 power distribution units (PDUs)
Daisy chain functions support SNMP and Modbus protocols as well as TC/IP protocols (website)
Supports ATEN's eco DC (Energy & DCIM Management Web GUI) for monitoring power distribution, energy and environmental data from PDUs and connected devices
Socket control
Control of sockets (on/off, off and restart) via individual sockets and socket groups
Support for outlet groups at PDU level
Supports multiple methods for controlling the power supply – Wake on LAN, System After AC Back, Kill the Power
Power-on sequencing – users can set the power-on sequence and delay time for each socket so that devices can be switched on in the correct order
Proactive overload protection (POP) – automatically switches off the last socket causing the power overload, while users can set the shutdown priority
Schedule control
When the temperature or humidity sensor value reaches the specified threshold, the PDU can turn a specific outlet on, off or restart it
Energy-efficient relays enable control of large amounts of power flow for lower energy consumption.
Content of delivery
1x 8-outlet 1U Eco PDU
1x rack mounting kit
1x foot pad set (4 pcs.)
1x RJ-45 to DB-9 cable
1x full-surface colour sticker
1x user manual
FunctionPG8308G
Electrical
Nominal input voltage100 – 240 VAC
Maximum input current32A Max
Input frequency50-60 Hz
Input connectionIEC 60309 32A
Input power7680VA(Max)
Output type(6) IEC320 C13+(2) IEC320 C19
Rated output voltage100 – 240 VAC
Maximum output current (output)C13:10A(Max)
C19:16A(Max)
Circuit breakerUL489x2
MeasurementPer socket: Current, voltage, power factor and kWh monitoring
Output changeYes
Ambient sensor ports1xRJ45
USB 2.0 Type-A portYes
Ethernet port10/100/1000M
PON + COM port1xRJ45
Measurement accuracy1%
Physical characteristics
Dimensions (L x W x H)43.24 x 21.00 x 4.40 cm
(17.02 x 8.27 x 1.73 in.)
Weight4.07 kg ( 8.97 lb )
Power cord length3M(SR+IEC60309 32A)
Environment
Temperature (operating/storage)0 – 60 / -20 – 60
Humidity (operating and storage)0 – 80% RH, non-condensing
Compliance
EMC verificationCE
Safety verificationCE, UKCA
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1558019
qrcode für Aten PG8308G-AT PDU 8-outlet 1U 32A