Further information for Aten PE7216G eco PDU 0HE 14x C13 2x C19 metering
Certificates
Certification
CE, TUV-CB, CE-LVD
Design
PDU types
Metered
Rack capacity
1.5U
Housing material
Metal
Product colour
Black
Features
Cable length
1.6 m
LED indicators
Management features
Monitoring
Current, Humidity
Management platform
SNMP v1/v2/v3
Operational conditions
Operating temperature (T-T)
0 - 40 °C
Storage temperature (T-T)
-20 - 60 °C
Operating relative humidity (H-H)
0 - 80%
Ports & interfaces
AC outlets quantity
16 AC outlet(s)
Power plug
C20 coupler
AC outlet types
C13 coupler, C19 coupler
Output connections
14 x IEC320 C13 & 2 x IEC320 C19
Power
Nominal input voltage
100-240 V
AC input frequency
50 - 60 Hz
Maximum current
16 A
Nominal output voltage
100-240 V
Load capacity
3680 VA
Technical data
Mounting
Vertical
Length packaging
1.415m
Number of C19 sockets
2
Packaging volume
0.0474m³
Width packaging
0.187m
Weight
6.140kg
Type
PDU
Height packaging
0.179m
Supply line
Power cable with C19 connector
Number of C13 sockets
14
Max. input power
3680VA
Output current
16A
Switching function
Input C20
Input C14
Input CE 16/32A
Protective function
Measuring function
Weight & dimensions
Width
66 mm
Depth
1325 mm
Height
44 mm
Weight
3.7 kg
As part of its NRGence line, ATEN has developed a new generation of green energy power distribution units (eco PDUs) to effectively increase the efficiency of data center power usage. The NRGence PE7216 eco PDUs are intelligent PDUs that contain 16 AC outlets and are available in various IEC socket configurations. NRGence eco PDUs provide secure, centralized, intelligent, power management of data center IT equipment (servers, storage systems, KVM switches, network devices, serial data devices, etc.), as well as the ability to monitor the center's health environment via sensors.
NRGence eco PDUs offer real-time power measurement — allowing you to monitor the power status of devices attached to the PDUs, either at the PDU device, bank, or outlet level, depending on the model, from practically any location via a TCP/IP connection. NRGence eco PDU supports any 3rd party V3 SNMP Manager Software and NRGence eco Sensors (eco PDU Manager Software). eco Sensors provides you with an easy method for managing multiple devices, offering an intuitive and user-friendly Graphical User Interface that allows you to configure a PDU device and monitor power status of the equipment connected to it.
With its advanced security features and ease of operation, the eco PDU is the most convenient, most reliable, and most cost effective way to remotely manage power access for multiple computer installations and allocate power resources in the most efficient way possible.
ConnectionsSupport 10/100Mbit Ethernet Interface
Support TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, Telnet, and SNMP V1,V2&V3
Support 2-level account/password security, IP/MAC filter, 128 bit SSL, RADIOUS
Support : eco Sensors, Browser ( IE, Firefox, Chrome, Safari )
MeteringPDU and outlet level power metering and monitoring
Environment monitoring – supports external temperature/temperature & humidity sensors for rack temperature and humidity monitoring
Current, voltage, power, power dissipation, temperature, and humidity metering and threshold level setting
Support door sensor
Outlet Switch ControlAlways On
Package Contents1x PE7216 eco PDU
1x Power Cord
1x Rack Mount Kit
1x CD-ROM (Manual, eco Sensors Software)
1x User Instructions
FunctionPE7216BPE7216G
Electrical
Nominal Input Voltage100 – 240 VAC100 – 240 VAC
Maximum Input Current20A Max; 16A(UL de-rated)16A Max
Input Frequency50-60 Hz50-60 Hz
Input ConnectionNEMA 6-20PIEC 60320 C20
Input Power4160 VA(Max); 3328 VA(UL de-rated)3680 VA(Max)
Outlet TypeTotal: 14 x IEC320 C13 + 2 x IEC320 C19
Bank1-1: Outlet 1 – 8; 7 x C13 + 1 x C19
Bank1-2: Outlet 9 – 16; 7 x C13 + 1 x C19Total: 14 x IEC320 C13 + 2 x IEC320 C19
Bank1-1: Outlet 1 – 8; 7 x C13 + 1 x C19
Bank1-2: Outlet 9 – 16; 7 x C13 + 1 x C19
Nominal Output Voltage100 – 240 VAC100 – 240 VAC
Maximum Output Current (Outlet)C13: 15A (Max); 12A(UL de-rated)
C19: 20A (Max); 16A(UL de-rated)C13: 10A (Max)
C19: 16A (Max); TUV De-rated 15A(Max)
Maximum Output Current (Bank)20A(Max); 16A(UL de-rated)16A(Max); TUV De-rated 15A(Max)
Maximum Output Current (Total)20A(Max); 16A(UL de-rated)16A(Max); TUV De-rated 15A(Max)
Breakers1 x 20A Non-Fuse breaker1 x 16A Non-Fuse breaker
MeteringOutlet Level Current, Voltage, VA, PF, KWh MonitoringOutlet Level Current, Voltage, VA, PF, KWh Monitoring
Outlet SwitchingNoneNone
Environment Sensor Ports44
Metering AccuracyVoltage Range: 100VAC ~ 250VAC +/-1%
Power Range: 100W ~ Maximum Capacity +/- 2%
Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%Voltage Range: 100VAC ~ 250VAC +/-1%
Power Range: 100W ~ Maximum Capacity +/- 2%
Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Physical Properties
Dimensions (L x W x H)132.48 x 6.60 x 4.40 cm
(52.16 x 2.6 x 1.73 in.)132.48 x 6.60 x 4.40 cm
(52.16 x 2.6 x 1.73 in.)
Weight3.70 kg ( 8.15 lb )3.70 kg ( 8.15 lb )
Power Cord Length1.6 m1.6 m
Environmental
Temperature (Operating / Storage)0 – 50°C / -20 – 60°C0 – 40°C / -20 – 60°C
Humidity (Operating & Storage)0 – 80% RH, Non-Condensing0 – 80% RH, Non-Condensing
Compliance
EMC VerificationFCC Part 15 Class A, Others by RequestCE, Others by Request
Safety VerificationTUV-CB, Others by RequestTUV-CB, CE-LVD, Others by Request
NoteFor some of rack mount products, please note that the standard physical dimensions of WxDxH are expressed using a LxWxH format.