Allnet ALL4454_black, EAN: 4038816102430

Allnet ALL4454_black Smoke Detector Gas Sensor black

Security Technology > Sensors > Fire & Gas Detectors

Allnet ALL4454_black Smoke Detector Gas Sensor black

Lieske Part No. 109414
Mfg Part No ALL4454_black
EAN-Code 4038816102430
Manufacturer Allnet
Here only 87,25 EUR
103,83 EUR incl. VAT

Further information for Allnet ALL4454_black Smoke Detector Gas Sensor black

Technical data
Application sites MSRindoor
Construction typeMetal housing
Compatibility with central unitALL4176
Sensor typeSmoke & Gas
The ALL4454 smoke detector/sensor from Allnet is a combined sensor for the detection of smoke and flammable gases, designed for use in building technology and industrial applications. The device features a flat, metallic housing made of aluminium, which can be used as either a desktop or wall-mounted unit. Wall mounting is enabled by integrated angle brackets. The sensor is specifically designed for indoor use and operates via an I2C bus, enabling connection to compatible MSR central units such as the ALL34xx, ALL3500, ALL4500, or ALL5000. The connection is made through two RJ45 connectors, enabling a multiplexing function where multiple sensors can be operated on a single physical port — provided the sensors have different I2C chip addresses and IDs. This is particularly possible with ARM- and MIPS-based systems, but not with the ALL3000/4000 models.

Applications

The ALL4454 is suitable for monitoring indoor spaces in buildings and industrial environments where early detection of smoke or flammable gases is required. Application areas include residential and office buildings, industrial plants, warehouses, and building technology facilities requiring intelligent control via network and internet. The integrated functionality enables central control and monitoring via an MSR central unit, allowing automated responses such as alarms, ventilation control, or emergency shutdowns to be initiated.

Functions and Equipment in Detail

The sensor is based on the Figaro TGS813, a MOS gas sensor made of tin dioxide (SnO2), designed for reliable detection of flammable gases such as methane, propane, and butane. In the presence of gases, the sensor resistance changes proportionally to the concentration, enabling simple and cost-efficient evaluation. The high sensitivity, good long-term stability, and easy integration make the TGS813 particularly suitable for gas warning and safety applications. Additionally, the sensor detects smoke, enabling it to function as a combined smoke and gas sensor. Integrated LED indicators (PWR and BUS) signal the operating status and communication over the bus.

Technology Explained Simply

The sensor operates via an I2C bus, implemented through two RJ45 connectors. This allows cascading multiple sensors on a single line, with a maximum cable length of 100 meters. Individual sensors are identified via software-configurable I2C chip addresses and IDs. Measured values are transmitted over the bus to the MSR central unit, where they are evaluated and used to define thresholds, rules, and actions. Calibration is recommended in fresh, well-ventilated air to capture the reference value for clean air. Subsequently, a test spray can be used to perform a functionality check and determine the alarm threshold.

Compatibility and Accessories

The ALL4454 is compatible with MSR central units ALL34xx, ALL3500, ALL4500, and ALL5000 that feature an I2C bus. Suitable central units include, for example, the ALL5000v2 with 16 sensor ports and 48,3 cm ( 19 inch ) form factor, the ALL3500v2 with 4 sensor ports and WLAN, and the ALL3419 with 3 sensor ports, WLAN, and integrated temperature sensor ALL3008. The connection is made via the RJ45 connectors, with the multiplexing function supported only on ARM- and MIPS-based systems.

Mounting and Installation

Mounting is either on a desktop or on a wall. The aluminium housing features integrated angle brackets for secure wall mounting. Installation requires connecting the two RJ45 connectors to the MSR central unit. Calibration is recommended after commissioning to ensure reliable measurement values. The operating temperature ranges from -45 °C to 90 °C, with operating humidity from 0 % to 100 % (non-condensing). Storage temperature ranges from -20 °C to 60 °C, with storage humidity from 5 % to 90 % (non-condensing).

Operational Advantages

The ALL4454 offers reliable and cost-efficient detection of smoke and flammable gases. The multiplexing function allows multiple sensors to be connected to a single port, simplifying installation and maintenance. Central control via network and internet enables independent, automated monitoring and response, regardless of time or location. The high sensitivity and long-term stability of the TGS813 sensor ensure lasting reliability. Integrated LED indicators facilitate diagnosis of the operating status. CE and RoHS markings confirm compliance with European standards.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/109414
qrcode für Allnet ALL4454_black Smoke Detector Gas Sensor black