Allnet ALL4442, EAN: 4038816018991

Allnet ALL4442 4-channel Contact Input Pulse Extension

Installation > Home Automation > Home Automation - Others

Allnet ALL4442 4-channel Contact Input Pulse Extension

Lieske Part No. 924226
Mfg Part No ALL4442
EAN-Code 4038816018991
Manufacturer Allnet
Here only 100,43 EUR
119,51 EUR incl. VAT

Further information for Allnet ALL4442 4-channel Contact Input Pulse Extension

General
Number of contact inputs4
Contact typeDry contact
Signal logicopen = 1, closed = 0
CompatibilityALL34xx, ALL350x, ALL4500, ALL5000, ALL3692
IncompatibilityALL3000, ALL4000
The Allnet ALL4442 is a 4-channel contact input module for integration into IP-based building automation systems. It serves as an interface for detecting states via potential-free contacts, for example from door or window switches, and is specifically designed for use in MSR central units of the Allnet product family. The module enables the connection of up to four independent contacts, where open contacts are interpreted as logical '1' and closed contacts as logical '0'. This logic is particularly suitable for idle current loops, where a short pulse (e.g. when opening a door) is converted into a longer signal state via pulse extension to ensure reliable detection in the system.

Applications

The module is suitable for use in building automation and home automation systems where binary states need to be detected via mechanical or electronic contacts. Typical applications include monitoring access points, windows, device switching states, or other binary sensors. The pulse extension ensures that short signals, such as those generated by mechanical contact interruptions, are correctly recognized and processed in the system.

Functions and Equipment in Detail

The ALL4442 features four isolated inputs, each capable of controlling a potential-free contact. The signals are digitized and transmitted to the higher-level MSR central unit. Contact evaluation follows the principle that an open contact indicates state '1' and a closed contact indicates state '0'. This logic is implemented by default in the firmware of compatible central units. The pulse extension ensures that short signals generated by mechanical movements are not lost but are interpreted as active for a defined period.

Technology Explained Simply

The module is housed in a metallic enclosure, enabling robust mounting. The inputs are galvanically isolated, ensuring safe and interference-free signal transmission. The pulse extension is an integrated function that ensures even short signals, such as those occurring with mechanical contacts, are detected in the system. This is particularly important to avoid false alarms or misinterpretations. Communication takes place via the integrated interface of the MSR central unit, with the exact protocol implementation determined by the specific central unit used.

Compatibility and Accessories

The module is compatible with MSR central units of types ALL34xx, ALL350x, ALL4500, ALL5000, and ALL3692. It is not compatible with models ALL3000 and ALL4000. Integration is achieved via the corresponding sensor ports on the central units. The product description mentions MSR central units ALL3419, ALL3500v2, and ALL5000v2 as accessories, each featuring multiple sensor ports and designed for IP-based building automation. The exact number of available ports varies depending on the central unit model.

Mounting and Installation

The module is housed in a metallic enclosure suitable for wall mounting. Installation involves connecting the contacts to the designated terminals and linking to the MSR central unit via the appropriate interface. The exact mounting instructions are included in the documentation for the respective central unit. Wiring is done via potential-free contacts, where polarity is irrelevant since the signals are galvanically isolated.

Operational Advantages

Using the ALL4442 enables reliable detection of binary states in building automation systems. The pulse extension reduces the likelihood of false alarms, as short signals are not ignored. Galvanic isolation of the inputs protects the system from interference and enhances operational safety. Compatibility with a range of MSR central units offers flexibility in system selection and allows for step-by-step expansion of the installation.

Protection Rating and Environmental Conditions

Installation is intended for indoor environments, with no specific environmental requirements mentioned.

Accessories and System Integration

The module is used in combination with MSR central units that feature corresponding sensor ports. The mentioned central units (ALL3419, ALL3500v2, ALL5000v2) offer varying numbers of ports and functions, with the ALL5000v2, for example, providing 16 sensor ports and a 48,3 cm ( 19 inch ) mounting option. Integration occurs via the I2C interface, which is implemented in compatible central units. Exact configuration is performed through the central unit's software.

Function of Pulse Extension

The pulse extension ensures that a short signal pulse, such as that generated by a mechanical contact, is converted into a longer signal. This is important to ensure the signal is detected in the system even during brief contact interruptions.

Application in Building Automation

In building automation, the module is used for state monitoring of doors, windows, switches, and other binary sensors. The data is transmitted to the MSR central unit, where it can be used for alarm functions, logic control, or visualizations. Integration occurs via the I2C interface, which is implemented in compatible central units. Exact configuration is performed through the central unit's software.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/924226
qrcode für Allnet ALL4442 4-channel Contact Input Pulse Extension