Allnet ALL369x-A800, EAN: 4038816000101

Allnet ALL369x-A800 Inductive Clamp Set 800A

Networks > Environmental Control

Allnet ALL369x-A800 Inductive Clamp Set 800A

Lieske Part No. 214376
Mfg Part No ALL369x-A800
EAN-Code 4038816000101
Manufacturer Allnet
Here only 398,60 EUR
474,33 EUR incl. VAT

Further information for Allnet ALL369x-A800 Inductive Clamp Set 800A

General
Number of terminals3
Maximum current per phase800 A
Terminal inner diameter30 mm
CompatibilityALLNET MSR Powermeter Series ALL3690/3691
Measurement principleInduction
Accessory forALLNET MSR Powermeter Central Unit ALL3696
The product is a 3-piece set of induction clamps for the ALLNET MSR power meter, specifically designed for measuring current strengths up to 800 amperes per phase in three-phase systems. The clamps serve as accessories for the power meter models of the ALL3690/3691 series and enable non-invasive current measurement via induction. The inner diameter of the clamps is 30 mm, allowing installation on conductors with a corresponding diameter. The clamps are intended for use in industrial and building automation environments where precise current monitoring is required.

Applications
The induction clamps are designed for use in electrical installations with high current loads, particularly in industrial and building automation. They are suitable for monitoring current consumption in three-phase networks, where each phase can be measured individually. The clamps are part of a comprehensive measurement system connected to the ALLNET MSR power meter to capture and analyze energy consumption data. The application is typically used in facilities requiring detailed energy balancing or load monitoring.

Functions and Equipment in Detail
The set consists of three identical induction clamps, each to be mounted on one phase of the three-phase circuit. The clamps operate on the principle of electromagnetic induction, enabling the flowing current to be detected without direct electrical contact. The inner diameter of 30 mm allows installation on conductors with a maximum diameter of 30 mm. The clamps are designed for a maximum current of 800 amperes per phase, making them suitable for medium to high loads. Installation is performed by opening the clamp, encircling the conductor, and closing the clamp, ensuring that the clamp is not closed under load.

Technology Explained Simply
The induction clamps utilize the principle of electromagnetic induction, where a changing magnetic field generated by the current in the conductor induces a secondary electrical signal in the clamp. This signal is transmitted to the power meter, which converts it into current values. The clamps are passive and require no external power supply, as they derive energy from the magnetic field of the conductor. Measurement is performed without interrupting the current flow, enabling disturbance-free installation. The clamps are designed for safe and reliable measurement in industrial environments.

Compatibility and Accessories
The induction clamps are specifically developed for the ALLNET MSR power meter models of the ALL3690/3691 series. They are part of a comprehensive measurement system that also includes the central unit ALL3696 with integrated S0 and D0 interfaces, as well as additional induction clamps. The combination with the central unit enables the collection and transmission of energy consumption data for building automation systems. The clamps are not intended for other measuring devices or systems, as they are specifically adapted to the interfaces and protocols of the ALLNET power meters.

Installation and Mounting
Installation of the induction clamps is performed by opening the clamp, encircling the conductor to be measured, and closing the clamp. The clamp must not be closed under load, as this may cause uncontrolled current distribution and potential damage. Installation should take place at a location where the conductor is accessible and the inner diameter of the clamp (30 mm) is sufficient to encircle the conductor. The clamps are designed for fixed mounting on the conductor, ensuring a secure connection to avoid measurement errors.

Operational Advantages
The induction clamps enable contactless and disturbance-free current measurement, allowing installation without interrupting the current flow. Measurement is precise and reliable, enabling accurate energy consumption analysis. The clamps are designed for industrial environments and offer high robustness. Compatibility with the ALLNET MSR power meter enables integrated energy monitoring, which can be used in building automation systems. The clamps are easy to install and require no special tools, allowing for quick and efficient installation.