Allnet ALL3688, EAN: 4038816001511

Allnet ALL3688 Optical D0 Reader Head

Installation > Home Automation > Home Automation - Others

Allnet ALL3688 Optical D0 Reader Head

Lieske Part No. 707952
Mfg Part No ALL3688
EAN-Code 4038816001511
Manufacturer Allnet
Here only 30,01 EUR
35,71 EUR incl. VAT

Further information for Allnet ALL3688 Optical D0 Reader Head

General
Product typeOptical D0 reader head
CompatibilityAllnet Powermeter central units ALL3691, ALL3692, ALL3696
Signal transmissionInfrared, D0 protocol
Signal updateevery 2 seconds
MountingMagnetic ring
The Allnet ALL3688 is an optical D0 reader head, specifically developed for use with Allnet MSR Powermeter central units. It is designed to receive the D0 signal from modern electricity meters installed by energy suppliers. The D0 signal is typically transmitted automatically every two seconds in the infrared range by the electricity meter. The reader head is mounted directly onto the front side of the electricity meter using a magnetic ring to receive the signal. Compatibility is limited to Allnet Powermeter central units with a D0 interface, such as models ALL3691, ALL3692, and ALL3696. Functionality is guaranteed only in combination with these devices and a compatible electricity meter. The exact technical requirements for compatibility with specific electricity meters are described in the manufacturer's datasheet.

Applications

The D0 reader head is used in building automation and energy management to capture electricity consumption in real time. It is suitable for installations in residential and commercial buildings where precise energy consumption measurement via the D0 protocol is required. The application is performed in conjunction with Allnet Powermeter central units, which transmit the data over IP networks. Integration into existing building management systems is possible if the central unit provides appropriate interfaces.

Functions and Equipment in Detail

The reader head is equipped with a magnetic ring, enabling secure and non-slip mounting onto the electricity meter. The optical receiving unit is tuned to the infrared signal of the D0 protocol, which is standardly transmitted by many modern electricity meters. Data acquisition is contactless, avoiding any mechanical stress on the meter. Signal transmission is continuous, with data being updated every two seconds. The connection to the Powermeter is established via the D0 interface, which is integrated into the mentioned Allnet models.

Technology Explained Simply

The D0 protocol is a standard for data transmission from electricity meters, widely used in Germany and other European countries. It enables the transmission of consumption data in the infrared range, with data being sent at short intervals, here every two seconds. The optical reader head captures these signals and forwards them to the Powermeter central unit, which processes the data and transmits it over IP networks to central control systems or visualization platforms. The technology is not complex but requires precise positioning of the reader head opposite the signal source on the meter.

Compatibility and Accessories

The ALL3688 is compatible exclusively with Allnet Powermeter central units featuring a D0 interface. This includes models ALL3691, ALL3692, and ALL3696. For example, the ALL3692 central unit offers four D0 interfaces, enabling simultaneous connection of multiple electricity meters. The ALL3696 central unit features one D0 interface and one S0 interface and is also designed for IP-based building automation. Exact compatibility with specific electricity meters is documented in the manufacturer's datasheet.

Installation and Mounting

Mounting is performed by attaching the reader head with its integrated magnetic ring directly to the front side of the electricity meter. Positioning must ensure that the optical receiver is directly opposite the infrared transmitter on the meter. Precise alignment is necessary to ensure reliable signal transmission. Installation requires no tools and can be carried out without electrical connections. The connection to the Powermeter is made via the D0 interface, which is already present in the central unit.

Operational Advantages

Using the D0 reader head enables precise and continuous monitoring of electricity consumption. Data is transmitted in real time, enabling efficient energy monitoring and control. The contactless data acquisition protects the electricity meter from mechanical stress. Integration into existing building automation systems is straightforward, as Powermeter central units communicate over IP networks. Maintenance is minimal, as no moving parts or electrical connections are required at the meter.