| General |
| Nominal power | 600 VA |
| Input voltage | 230 V |
| Output voltage | 230 V |
| Test voltage | 4 kV |
| Number of outputs | 6 |
| Ambient temperature | 40 °C |
| Storage temperature | -10 to +50 °C |
| Colour | RAL 7035 light grey |
| Standards | IEC 60601-1 3rd Edition, EN 60601-1 3rd Edition, EN 60601-1-2, IEC 60601-1-2, UL 60601-1, CSA C22.2 No. 601.1-M90, TÜV – geprüft |
| Making damping | Electronic |
This medical isolation transformer of the MED R 3rd series is designed for use in medical facilities, where electrical safety of patients and operating personnel has the highest priority. It features a rated power of 600 VA and is tested according to the 3rd Edition of the standard IEC 60601-1:2005, confirming compliance with current safety requirements for medical electrical equipment. The input and output voltage is 230 V each, allowing direct connection to the public power grid without requiring voltage conversion. The separation between primary and secondary windings ensures galvanic isolation, minimizing leakage currents and thus increasing safety when using medical devices.
Applications
The isolation transformer is suitable for use in hospitals, clinics, laboratories, and other medical facilities where electrical devices come into direct contact with patients. It protects against dangerous electrical voltages and prevents failures caused by voltage spikes. The compact design allows flexible placement, even in confined spaces, and the integrated rubber feet ensure stable positioning on flat surfaces.
Functions and Equipment in Detail
The transformer features six outputs, suitable for simultaneously powering multiple medical devices. The electronic inrush current suppression reduces current surges occurring at switch-on and protects sensitive devices from damage. The test voltage is 4 kV between primary and secondary windings, confirming insulation strength and safety under extreme conditions. The RAL 7035 light grey color ensures unobtrusive integration into medical environments.
Technology Explained Simply
The galvanic isolation between input and output side prevents electrical currents from flowing directly from the grid into connected devices. This is particularly important when patients are in contact with electrically powered devices, as it minimizes the risk of electric shocks or leakage currents. Compliance with the IEC 60601-1 3rd Edition standard ensures the transformer meets strict requirements for safety and EMC (Electromagnetic Compatibility). The EMC standard EN 60601-1-2 ensures the transformer does not cause interference in other devices and is itself immune to electromagnetic disturbances.
Compatibility and Accessories
The isolation transformer is designed for use with medical devices requiring 230 V. It is equipped with a mounting rail, enabling secure attachment to a standard rail system, which facilitates integration into existing installations. Conformity with standards also includes certifications UL 60601-1 and CSA C22.2 No. 601.1-M90, supporting international usability.
Installation and Mounting
Installation is performed by connecting to the 230 V grid and securing to a suitable mounting rail. Dimensions are 95 mm (height) × 170 mm (width) × 270 mm (depth), with the rubber feet adding an additional 6 mm in height. The ambient temperature must not exceed 40 °C, and the storage temperature ranges between -10 °C and +50 °C. The mounting rail enables secure fastening, allowing the transformer to be stably positioned even in mobile environments.
Operational Advantages
Operation of the isolation transformer is disturbance-free and reliable. Galvanic isolation protects patients and operating personnel, while electronic inrush current suppression extends the lifespan of connected devices. Compliance with international standards ensures high safety standards and facilitates approval in various countries. The compact design and integrated mounting rail support flexible and quick installation in medical facilities.